Strengthening fetal heart rate monitoring during labor with a standard handheld doppler – Implementation experience from India

التفاصيل البيبلوغرافية
العنوان: Strengthening fetal heart rate monitoring during labor with a standard handheld doppler – Implementation experience from India
المؤلفون: Devina Bajpayee, Enisha Sarin, Sourav Ghosh Dastidar, Subodh Chandra, Jaya Swarup Mohanty, Nitin Bisht, Arvind Kumar, Harish Kumar
المصدر: Indian Journal of Community Medicine, Vol 47, Iss 3, Pp 405-409 (2022)
بيانات النشر: Wolters Kluwer Medknow Publications, 2022.
سنة النشر: 2022
المجموعة: LCC:Public aspects of medicine
مصطلحات موضوعية: aspirational districts, doppler, fetal heart rate monitoring, india, laqshya, maternal health, newborn health, Public aspects of medicine, RA1-1270
الوصف: Background: India's neonatal and perinatal mortality is among the highest in the world. Intrapartum-related conditions contribute to a significant proportion of neonatal deaths and stillbirths. Fetal heart rate monitoring, a recommended norm to assess fetal well-bring, is not practiced as per standard guidelines in public health facilities. A standardized Doppler along with training on fetal heart rate monitoring was implemented across different levels of healthcare in three states. Methods: Facilities were selected purposively to implement the Doppler. Baseline data for 3 months were collected. Interviews of health providers and observation of labor were conducted quarterly. Data were analyzed through a comparison of baseline and intervention on a number of delivery and monitoring indicators. Results: Among 22,579 total deliveries, monitoring frequency increased along with increase in detection of abnormal fetal heart rate (FHR) while cesarean section and stillbirths reduced slightly. Cases never monitored reduced in the District Hospitals (7.98–2.07, P < 0.01) and in Community Health Centers (14.7–1.67, P < 0.001). Stillbirth rate reduced at the medical college (3.6–1.1, P < 0.001). Interviews with providers revealed acceptance of the device due to its reliable readings. Conclusion: The Doppler demonstrates acceptability and serves as a useful aid to improve intrapartum FHR monitoring.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0970-0218
1998-3581
Relation: http://www.ijcm.org.in/article.asp?issn=0970-0218;year=2022;volume=47;issue=3;spage=405;epage=409;aulast=Bajpayee; https://doaj.org/toc/0970-0218; https://doaj.org/toc/1998-3581
DOI: 10.4103/ijcm.ijcm_818_21
URL الوصول: https://doaj.org/article/5e3eeceaa3554fb185b0a20f8be10867
رقم الأكسشن: edsdoj.5e3eeceaa3554fb185b0a20f8be10867
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09700218
19983581
DOI:10.4103/ijcm.ijcm_818_21