Validation of the relative biological effectiveness of active-energy scanning carbon-ion radiotherapy on a commercial treatment planning system with a microdosimetic kinetic model

التفاصيل البيبلوغرافية
العنوان: Validation of the relative biological effectiveness of active-energy scanning carbon-ion radiotherapy on a commercial treatment planning system with a microdosimetic kinetic model
المؤلفون: Weiwei Wang, Wei Sun, Hao Shen, Jingfang Zhao
المصدر: Radiation Oncology, Vol 18, Iss 1, Pp 1-10 (2023)
بيانات النشر: BMC, 2023.
سنة النشر: 2023
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: CIRT, MKM, Validation, RayStation, Active scanning, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Abstract Background The study objective was to validate the relative biological effectiveness (RBE) calculated by the modified microdosimetric kinetic model in RayStation (Ray-MKM) for active-energy scanning carbon-ion radiotherapy. Methods The Ray-MKM was benchmarked using a spread-out Bragg-peak (SOBP) plan, which was suggested in literature from the National Institute of Radiobiological Science (NIRS) in Japan. The residual RBE differences from the MKM at NIRS (NIRS-MKM) were derived using several SOBP plans with different ranges, SOBP widths, and prescriptions. To investigate the origins of the differences, we compared the saturation-corrected dose-mean specific energy $$Z_{1D}^{*}$$ Z 1 D ∗ of the aforementioned SOBPs. Furthermore, we converted the RBE-weighted doses with the Ray-MKM to those with local effect model I (LEM doses). The purpose was to investigate whether the Ray-MKM could reproduce the RBE-weighted conversion study. Results The benchmark determined the value of the clinical dose scaling factor, $$F_{clin}$$ F clin , as 2.40. The target mean RBE deviations between the Ray-MKM and NIRS-MKM were median: 0.6 (minimum: 0.0 to maximum: 1.69) %. The $$Z_{1D}^{*}$$ Z 1 D ∗ difference in-depth led to the RBE difference in-depth and was remarkable at the distal end. The converted LEM doses from the Ray-MKM doses were comparable (the deviation being − 1.8–0.7%) to existing literature. Conclusion This study validated the Ray-MKM based on our active-energy scanning carbon-ion beam via phantom studies. The Ray-MKM could generate similar RBEs as the NIRS-MKM after benchmarking. Analysis based on $$Z_{1D}^{*}$$ Z 1 D ∗ indicated that the different beam qualities and fragment spectra caused the RBE differences. Since the absolute dose differences at the distal end were small, we neglected them. Furthermore, each centre may determine its centre-specific $$F_{clin}$$ F clin based on this approach.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1748-717X
Relation: https://doaj.org/toc/1748-717X
DOI: 10.1186/s13014-023-02267-8
URL الوصول: https://doaj.org/article/65ad70edc48d48c79e65a57c5ec140af
رقم الأكسشن: edsdoj.65ad70edc48d48c79e65a57c5ec140af
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1748717X
DOI:10.1186/s13014-023-02267-8