دورية أكاديمية

THE DIFFERENCESS OF DISCONTINUITAS IUD IN POST PLACENTAL AND INTRA-CESAREAN IN MADIUN

التفاصيل البيبلوغرافية
العنوان: THE DIFFERENCESS OF DISCONTINUITAS IUD IN POST PLACENTAL AND INTRA-CESAREAN IN MADIUN
المؤلفون: Melynda Trilamsari Putri, Ashon Sa'adi, Ivon Diah Wittiarika, Gadis Meinarsari
المصدر: Indonesian Midwifery and Health Sciences Journal, Vol 5, Iss 3, Pp 299-306 (2021)
بيانات النشر: Universitas Airlangga, 2021.
سنة النشر: 2021
المجموعة: LCC:Nursing
LCC:Gynecology and obstetrics
مصطلحات موضوعية: post placental iud, intrasecarean iud, discontinuity, Nursing, RT1-120, Gynecology and obstetrics, RG1-991
الوصف: Abstract Background: Intra Uterine Device (IUD) which is placed after delivery of the placenta is an attempt to reduce the rate of population growth. However, the achievement is still very low, especially in the post-placental IUD insertion. It is this high expulsion rate that continues to be a concern for service providers, so this method is acceptable. The purpose of this study is to compare the sustainability of IUD acceptors in post-placental and intra-cesareann placement. Methods: The design of this study was cross sectional with an observational analytic method. Location of this research in the family planning clinic of Dr. Soedono Madiun Hospital, Banjarejo Health Center, Tawangrejo Health Center, and PMB Ny. “P” Madiun City in 2019.The sample used consecutive sampling as many as 114 acceptors. The independent variable was the time of IUD insertion. The dependent variable is the discontinuity of the IUD acceptor. The instrument used was the 2019 IUD acceptor medical record. The Fisher Exact Test on SPSS was used to perform data analysis. Results: From 114 acceptors, there was no difference in the discontinuity of IUD acceptors in post-placental and intra-cesarean placement (p=0.1). The incidence of expulsion was found in post-placental insertion (p=0.02). In intra-cesarean IUD acceptors more confirmed using ultrasound examination (p = 0.03). There was no perforation in both. Conclusion: There is no difference in IUD acceptor discontinuity in post-placental and intra-cesarean placement.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Indonesian
تدمد: 2656-7806
Relation: https://e-journal.unair.ac.id/IMHSJ/article/view/27486; https://doaj.org/toc/2656-7806
DOI: 10.20473/imhsj.v5i3.2021.299-306
URL الوصول: https://doaj.org/article/756288702e324720bab1377b26860c5c
رقم الأكسشن: edsdoj.756288702e324720bab1377b26860c5c
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:26567806
DOI:10.20473/imhsj.v5i3.2021.299-306