دورية أكاديمية

Stenosis Detection From Time-of-Flight Magnetic Resonance Angiography via Deep Learning 3D Squeeze and Excitation Residual Networks

التفاصيل البيبلوغرافية
العنوان: Stenosis Detection From Time-of-Flight Magnetic Resonance Angiography via Deep Learning 3D Squeeze and Excitation Residual Networks
المؤلفون: Hunjin Chung, Koung Mi Kang, Mohammed A. Al-Masni, Chul-Ho Sohn, Yoonho Nam, Kanghyun Ryu, Dong-Hyun Kim
المصدر: IEEE Access, Vol 8, Pp 43325-43335 (2020)
بيانات النشر: IEEE, 2020.
سنة النشر: 2020
المجموعة: LCC:Electrical engineering. Electronics. Nuclear engineering
مصطلحات موضوعية: Stenosis detection, magnetic resonance angiography, internal carotid artery, deep learning, squeeze and excitation, residual networks, Electrical engineering. Electronics. Nuclear engineering, TK1-9971
الوصف: Intracranial artery stenosis is an important public health concern internationally, due to it being one of the major causes of ischemic stroke. In this study, we aim to provide a computer-aided diagnosis algorithm capable of automatically distinguishing between Internal Carotid Artery (ICA) stenosis and normal to minimize the labor-intensiveness of stenosis detection. Using Time-of-Flight Magnetic Resonance Angiography (TOF-MRA), a novel deep learning detection model via 3D Squeeze and Excitation Residual Networks (SE-ResNet) is proposed. Pre-processing of TOF-MRA, data augmentation, training of 3D SE-ResNet, and testing using patch-based and patient-based methods with cross-validation is described. The proposed network using a database consisting of 50 normal cases (ICA-N) and 41 stenosis cases (ICA-S) with grade level of above 30% was evaluated. All 41 ICA-S cases were categorized according to the diameter (D_stenosis) of the artery at the site of the most severe stenosis by expert radiologists, whereas percent stenosis was measured by Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) method. The proposed 3D SE-ResNet was further compared with more conventional networks including 3D ResNet and 3D VGG. The results showed the capability to detect stenosis achieving overall Area Under the Curve (AUC) and accuracies of 0.947 and 91.0% for patch-based and 0.884 and 81.0% for patient-based testing, respectively. In addition, the proposed 3D SE-ResNet achieved better performance against conventional 3D ResNet and 3D VGG with improvement rates of 0.053 and 0.095 for patch-based and 0.053 and 0.065 for patient-based testing in terms of AUC, respectively.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2169-3536
Relation: https://ieeexplore.ieee.org/document/9020109/; https://doaj.org/toc/2169-3536
DOI: 10.1109/ACCESS.2020.2977669
URL الوصول: https://doaj.org/article/7d8b195406a545b8984eb582f5461113
رقم الأكسشن: edsdoj.7d8b195406a545b8984eb582f5461113
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21693536
DOI:10.1109/ACCESS.2020.2977669