دورية أكاديمية

A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study

التفاصيل البيبلوغرافية
العنوان: A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study
المؤلفون: Jie Xiao, Haojun Yu, Xiuli Sui, Guobing Liu, Yanyan Cao, Zhao Yanzhao, Yiqiu Zhang, Pengcheng Hu, Dengfeng Cheng, Hongcheng Shi
المصدر: Cancer Imaging, Vol 22, Iss 1, Pp 1-13 (2022)
بيانات النشر: BMC, 2022.
سنة النشر: 2022
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Image quality, Variable acquisition time regimen, Total-body PET, 68 Ga-DOTATATE, PET/CT imaging, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Abstract Background The injection activity of tracer, acquisition time, patient-specific photon attenuation, and large body mass, can influence on image quality. Fixed acquisition time and body mass related injection activity in clinical practice results in a large difference in image quality. Thus, this study proposes a patient-specific acquisition time regimen of 68 Ga-DOTATATE total-body positron emission tomography-computed tomography (PET/CT) to counteract the influence of body mass (BM, kg) on image quality, and acquire an acceptable and constant image of patients with neuroendocrine tumors (NETs). Methods The development cohort consisting of 19 consecutive patients with full activity (88.7–204.9 MBq, 2.0 ± 0.1 MBq/kg) was to establish the acquisition time regimen. The liver SNR (signal-to-noise ratio, SNRL) was normalized (SNRnorm) by the product of injected activity (MBq) and acquisition time (min). Fitting of SNRnorm against body mass (BM, kg) in linear correlation was performed. Subjective assessment of image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL, and an optimized acquisition regimen based on BM was proposed, and validated its feasibility through the validation cohort of 57 consecutive NET patients with half activity (66.9 ± 11.3 MBq, 1.0 ± 0.1 MBq/kg) and a fixed acquisition time regimen. Results The linear correlation (R 2 = 0.63) between SNRnorm and BM (kg) was SNRnorm = -0.01*BM + 1.50. The threshold SNRL of acceptable image quality was 11.2. The patient-specific variable acquisition time regimen was determined as: t (min) = 125.4/(injective activity)*(-0.01*BM + 1.50)2. Based on that proposed regimen, the average acquisition time for acceptable image quality in the validation cohort was 2.99 ± 0.91 min, ranging from 2.18 to 6.35 min, which was reduced by 36.50% ~ 78.20% compared with the fixed acquisition time of 10 min. Subjective evaluation showed that acceptable image quality could be obtained at 3.00 min in the validation group, with an average subjective score of 3.44 ± 0.53 (kappa = 0.97, 95% CI: 0.96 ~ 0.98). Bland–Altman analysis revealed good agreement between the proposed regimen and the fixed acquisition time cohort. Conclusion A patient-specific acquisition time regimen was proposed in NET patients in development cohort and validated its feasibility in patients with NETs in validation cohort by 68 Ga-DOTATATE total-body PET/CT imaging. Based on the proposed regimen, the homogenous image quality with optimal acquisition time was available independent of body mass.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1470-7330
Relation: https://doaj.org/toc/1470-7330
DOI: 10.1186/s40644-022-00517-8
URL الوصول: https://doaj.org/article/81fc43b15aff41a59e891a3a00b8035a
رقم الأكسشن: edsdoj.81fc43b15aff41a59e891a3a00b8035a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14707330
DOI:10.1186/s40644-022-00517-8