دورية أكاديمية

Expertise in colonoscopy intubation does not predict diagnostic accuracy: a simulation-based study

التفاصيل البيبلوغرافية
العنوان: Expertise in colonoscopy intubation does not predict diagnostic accuracy: a simulation-based study
المؤلفون: Andreas S. Vilmann, Christian Lachenmeier, Morten Bo S. Svendsen, Bo Soendergaard, Yoon S. Park, Lars Bo Svendsen, Lars Konge
المصدر: Endoscopy International Open, Vol 10, Iss 01, Pp E30-E36 (2022)
بيانات النشر: Georg Thieme Verlag KG, 2022.
سنة النشر: 2022
المجموعة: LCC:Diseases of the digestive system. Gastroenterology
مصطلحات موضوعية: Diseases of the digestive system. Gastroenterology, RC799-869
الوصف: Background and study aims Studies have linked cecal intubation rate with adenoma detection rate; however, the direct association between technical performance during colonoscopy intubation and withdrawal has never been explored. Thus, it remains unclear whether gentle and efficient intubation predicts superior mucosal inspection. The aim of this study was to investigate the correlation between performance during intubation and withdrawal in a simulation-based setup. Methods Twenty-four physicians with various experience in colonoscopy performed twice on the Endoscopy Training System (ETS). Intubation skills were evaluated by assessing tasks on the ETS related to intubation (scope manipulation and loop management) and use of a computerized assessment tool called the 3D-Colonoscopy Progression Score (3D-CoPS). Diagnostic accuracy was defined by the number of polyps found during the ETS task of mucosal inspection. Pearson’s correlations were calculated to explore associations between intubation skill and diagnostic accuracy. Results The correlation analysis between 3D-CoPS and number of polyps found during mucosal inspection revealed a weak and insignificant correlation (0.157, P = 0.3). Likewise, an insignificant correlation was seen between ETS intubation and number of polyps found (0.149, P = 0.32). Conclusions We found no evidence to support that technical performance during intubation is correlated with mucosal inspection performance in a simulation-based setting.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2364-3722
2196-9736
Relation: https://doaj.org/toc/2364-3722; https://doaj.org/toc/2196-9736
DOI: 10.1055/a-1618-5525
URL الوصول: https://doaj.org/article/a9898ed091c040b39bb0b3ff38f779f5
رقم الأكسشن: edsdoj.9898ed091c040b39bb0b3ff38f779f5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23643722
21969736
DOI:10.1055/a-1618-5525