دورية أكاديمية

Simultaneous determination of vitamin D metabolites 25(OH)D3 and 1α,25(OH)2D3 in human plasma using liquid chromatography tandem mass spectrometry

التفاصيل البيبلوغرافية
العنوان: Simultaneous determination of vitamin D metabolites 25(OH)D3 and 1α,25(OH)2D3 in human plasma using liquid chromatography tandem mass spectrometry
المؤلفون: Shan Xu, Rui Ni, Lihong Lv, Rui Chen, Yao Chen, Fengjiao Huang, Zhiru Xu
المصدر: Journal of Mass Spectrometry and Advances in the Clinical Lab, Vol 24, Iss , Pp 65-79 (2022)
بيانات النشر: Elsevier, 2022.
سنة النشر: 2022
المجموعة: LCC:Medical technology
مصطلحات موضوعية: 25(OH)D3, , 25(OH)2D3, LC-MS/MS, Pharmacokinetics, Plasma, Medical technology, R855-855.5
الوصف: Background: Although measurement of 25(OH)D3 is a routine analytical method to determine plasma vitamin D status, 1α,25(OH)2D3 is the biologically active form. Hence, simultaneous measurement of 25(OH)D3 and 1α,25(OH)2D3 could provide better insight into vitamin D status and pharmacokinetics. However, 1α,25(OH)2D3 has a low plasma concentration, making its quantification challenging for most analytical techniques. Here, we demonstrate use of liquid chromatography tandem mass spectrometry (LC-MSMS) for the development of a simple and rapid method for the simultaneous quantification of 25(OH)D3 and 1α,25(OH)2D3. Methods: Samples were purified from 250 µL human plasma. Chromatography was performed on an analytical column, under gradient conditions using a mobile phase consisting of methanol-lithium acetate. The mass detector was operated in positive multiple reaction monitoring mode. The established method was validated according to the guidance issued by ICH and FDA. Furthermore, a clinical study was performed using this method to detect the plasma concentrations of 1α,25(OH)2D3 after oral administration of calcitriol. Results and conclusion: The method was acceptably linear over the concentration ranges of 20–1200 pg/mL for 1α,25(OH)2D3 and 1–60 ng/mL for 25(OH)D3, respectively, with correlation coefficients of r2 > 0.993. Both the inter-assay and intra-assay precision was
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2667-145X
Relation: http://www.sciencedirect.com/science/article/pii/S2667145X22000098; https://doaj.org/toc/2667-145X
DOI: 10.1016/j.jmsacl.2022.04.001
URL الوصول: https://doaj.org/article/9a902ee5523c44229bd0329c329b24eb
رقم الأكسشن: edsdoj.9a902ee5523c44229bd0329c329b24eb
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2667145X
DOI:10.1016/j.jmsacl.2022.04.001