دورية أكاديمية

SECOND-DERIVATIVE SPECTROPHOTOMETRY FOR THE ANALYSIS OF SIMVASTATIN IN POLYMERIC NANOCAPSULES

التفاصيل البيبلوغرافية
العنوان: SECOND-DERIVATIVE SPECTROPHOTOMETRY FOR THE ANALYSIS OF SIMVASTATIN IN POLYMERIC NANOCAPSULES
المؤلفون: Patrícia Gomes, Carla M. U. Negretto, Zanandria B. Naisinger, Ricardo Lorenzoni, Nathalie Ribeiro Wingert, Renata P. Raffin
المصدر: Drug Analytical Research, Vol 3, Iss 2, Pp 12-17 (2019)
بيانات النشر: Universidade Federal do Rio Grande do Sul, 2019.
سنة النشر: 2019
المجموعة: LCC:Biotechnology
LCC:Chemistry
مصطلحات موضوعية: method validation, nanocapsules, second-derivative spectroscopy, simvastatin, Biotechnology, TP248.13-248.65, Chemistry, QD1-999
الوصف: Conventional spectrophotometry methods are very susceptible to the presence of interferences in complex mixtures such as nanoparticules, requiring prior treatment or extraction of the analyte, and not always providing an adequate response. Derivative spectrophotometry method is capable to eliminate its interference; it is an alternative method for drugs determination in complex matrices. This work investigated the utility of derivate spectrophotometry in assay of simvastatin in polymeric nanocapsules (SIVNC). Shimadzu® UV-1650 double-beam spectrophotometer with 1.0 cm quartz cells was used in this study. The second-order deriva­tive spectrum was obtained employing Δλ=20,000 nm and scaling factor=9.0. The determinations were made at 239 nm (2D239) by zero-crossing method. 2D239 method was validated employing the parameters: specificity, linearity, robustness, precision and accuracy. Results: The specificity test showed there was no interference of constituents commonly found in SIVNC formulation in 2D239. The standard curve showed a correlation coefficient of 0.994. The robustness was evaluated by small changes in the conditions of sample analysis and however, no significant changes were observed regarding drug quantitation. The precision was demonstrated by relative standard deviation (RSD) of intra-day (RSD=1.61-3.76) and inter-day studies (RSD=2.32). The recovery test resulted in an average of 100.66%, which confirmed the accuracy of the method. The procedure was simple and rapid; therefore this technique offers an alternative for determination of SIVNC without interferences.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2527-2616
Relation: https://seer.ufrgs.br/dar/article/view/98057/55306; https://doaj.org/toc/2527-2616
DOI: 10.22456/2527-2616.98057
URL الوصول: https://doaj.org/article/b45d9dce588b40e58cedfcf31edb92f8
رقم الأكسشن: edsdoj.b45d9dce588b40e58cedfcf31edb92f8
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:25272616
DOI:10.22456/2527-2616.98057