دورية أكاديمية

Can placental shear wave elastography predict preeclampsia in high-risk pregnant women during second trimester? Insights from a prospective cohort study

التفاصيل البيبلوغرافية
العنوان: Can placental shear wave elastography predict preeclampsia in high-risk pregnant women during second trimester? Insights from a prospective cohort study
المؤلفون: Vikas Singh, Rajiv Kapoor, Monisha Modi, Sangeeta Singhal, Lovely Jain
المصدر: The Egyptian Journal of Radiology and Nuclear Medicine, Vol 55, Iss 1, Pp 1-9 (2024)
بيانات النشر: SpringerOpen, 2024.
سنة النشر: 2024
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: High-risk pregnancy, Placenta, Shear wave elastography, Preeclampsia, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: Abstract Background Preeclampsia, a condition very frequently linked to maternal and fetal deaths worldwide, remains a pressing concern due to delays in recognition and response. Effective screening tests for early detection of high-risk cases and appropriate preventive measures are currently lacking. Well planned prenatal care, timely detection, monitoring, and appropriate management are vital to prevent preeclampsia-related fatalities. Methods This prospective study evaluated the use of shear wave elastography (SWE) in identifying placental structural issues caused by preeclampsia in high-risk pregnancies. A total of 143 high-risk pregnant women with singleton pregnancies and an anterior placental position were included in the study. Results Women with preeclampsia exhibited significantly elevated SWE values in both center (27.98 ± 16.12 vs. 4.57 ± 6.57 kPa) and peripheral areas of the placenta (29.14 ± 16.12 vs. 4.80 ± 7.70 kPa) when compared to non-preeclampsia women (p = 0.000). Cutoff values of 8.70 kPa and 8.15 kPa at the Center and edge of the placenta respectively, accurately predicted preeclampsia in second-trimester pregnancies, with 84.62% sensitivity and 94% specificity. However no significant difference was observed between elastography values obtained from the center and edge of the placenta. Conclusions In conclusion, shear wave elastography can help diagnose preeclampsia early by assessing placental stiffness.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2090-4762
Relation: https://doaj.org/toc/2090-4762
DOI: 10.1186/s43055-024-01205-2
URL الوصول: https://doaj.org/article/cbbc01b6e51642cf80f493e81b7b18d2
رقم الأكسشن: edsdoj.bbc01b6e51642cf80f493e81b7b18d2
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20904762
DOI:10.1186/s43055-024-01205-2