دورية أكاديمية

Hybrid versus total sublaminar wires in patients with spinal muscular atrophy undergoing scoliosis surgery

التفاصيل البيبلوغرافية
العنوان: Hybrid versus total sublaminar wires in patients with spinal muscular atrophy undergoing scoliosis surgery
المؤلفون: Shih-Hsiang Chou, Wen-Wei Li, Cheng-Chang Lu, Kun-Ling Lin, Sung-Yen Lin, Po-Chih Shen, Yin-Chun Tien, Hsuan-Ti Huang
المصدر: BMC Musculoskeletal Disorders, Vol 22, Iss 1, Pp 1-8 (2021)
بيانات النشر: BMC, 2021.
سنة النشر: 2021
المجموعة: LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Spinal muscular atrophy, Segmental instrumentation, Sublaminar wire, Hybrid constructs, Scoliosis, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background Early versions of spinal muscular atrophy (SMA) scoliosis correction surgery often involved sublaminar devices. Recently, the utilization of pedicle screws has gained much popularity. Pedicle screws are generally believed to provide additional deformity correction, but pedicle size and rotational deformity limit their application in the thoracic spine, resulting in a hybrid construct involving pedicle screws and sublaminar wire. Studies of the efficacy of hybrid instrumentation in SMA scoliosis are often limited by the scarcity of the disease itself. In this study, we aimed to compare the surgical outcomes between hybrid constructs involving pedicle screws and sublaminar wire and sublaminar wire alone in patients with SMA scoliosis. Methods We retrospectively reviewed the clinical records and radiographic assessments of patients with SMA scoliosis who underwent corrective surgery between 1993 and 2017. The radiographic assessments included deformity correction and progressive changes in the major curve angle, pelvic tilt (PT) and coronal balance (CB). The correction of deformities was observed postoperatively and at the patient’s 2-year follow-up to test the efficacy of each type of construct. Results Thirty-three patients were included in this study. There were 14 and 19 patients in the wiring and hybrid construct groups, respectively. The hybrid construct group demonstrated a higher major curve angle correction (50.5° ± 11.2° vs. 36.4° ± 8.4°, p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2474
Relation: https://doaj.org/toc/1471-2474
DOI: 10.1186/s12891-021-04737-0
URL الوصول: https://doaj.org/article/f3ad79163abf46cca1a4909502f9f819
رقم الأكسشن: edsdoj.f3ad79163abf46cca1a4909502f9f819
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712474
DOI:10.1186/s12891-021-04737-0