Quality Assurance for Small-Field VMAT SRS and Conventional-Field IMRT Using the Exradin W1 Scintillator

التفاصيل البيبلوغرافية
العنوان: Quality Assurance for Small-Field VMAT SRS and Conventional-Field IMRT Using the Exradin W1 Scintillator
المؤلفون: Zike Huang MS, Jian Qiao PhD, Cui Yang MS, Ming Liu MD, Jiazhou Wang PhD, Xu Han MS, Weigang Hu PhD
المصدر: Technology in Cancer Research & Treatment, Vol 20 (2021)
بيانات النشر: SAGE Publishing, 2021.
سنة النشر: 2021
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Background: Plastic scintillator detector (PSD) Exradin W1 has shown promising performance in small field dosimetry due to its water equivalence and small sensitive volume. However, few studies reported its capability in measuring fields of conventional sizes. Therefore, the purpose of this study is to assess the performance of W1 in measuring point dose of both conventional IMRT plans and VMAT SRS plans. Methods: Forty-seven clinical plans (including 29 IMRT plans and 18 VMAT SRS plans with PTV volume less than 8 cm 3 ) from our hospital were included in this study. W1 and Farmer-Type ionization chamber Exradin A19 were used in measuring IMRT plans, and W1 and microchamber Exradin A16 were used in measuring SRS plans. The agreement between the results of different types of detectors and TPS was evaluated. Results: For IMRT plans, the average differences between measurements and TPS in high-dose regions were 0.27% ± 1.66% and 0.90% ± 1.78% ( P = 0.056), and were −0.76% ± 1.47% and 0.37% ± 1.34% in low-dose regions ( P = 0.000), for W1 and A19, respectively. For VMAT SRS plans, the average differences between measurements and TPS were −0.19% ± 0.96% and −0.59% ± 1.49% for W1 and A16 with no statistical difference ( P = 0.231). Conclusion: W1 showed comparable performance with application-dedicated detectors in point dose measurements for both conventional IMRT and VMAT SRS techniques. It is a potential one-stop solution for general radiotherapy platforms that deliver both IMRT and SRS plans.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1533-0338
15330338
Relation: https://doaj.org/toc/1533-0338
DOI: 10.1177/15330338211036542
URL الوصول: https://doaj.org/article/f4d3b0f3c3664269ab15a2590dfd079d
رقم الأكسشن: edsdoj.f4d3b0f3c3664269ab15a2590dfd079d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:15330338
DOI:10.1177/15330338211036542