دورية أكاديمية

Development and validation of a UV spectrophotometric method for biowaiver studies in pyrazinamide tablets

التفاصيل البيبلوغرافية
العنوان: Development and validation of a UV spectrophotometric method for biowaiver studies in pyrazinamide tablets
المؤلفون: Vanessa Saldaña-Bobadilla, Cintia P. Barreto-Villanueva, Frizzi J. Ganoza-Gasco, Enma Perez-Chauca, Olga E. Caballero-Aquiño, Ana E. Mantilla-Rodriguez, Pedro M. Alva-Plasencia, Maria S. Aurora-Prado
المصدر: Journal of Pharmacy & Pharmacognosy Research, Vol 12, Iss 3, Pp 539-547 (2024)
بيانات النشر: GarVal Editorial Ltda., 2024.
سنة النشر: 2024
المجموعة: LCC:Therapeutics. Pharmacology
LCC:Pharmacy and materia medica
مصطلحات موضوعية: antitubercular drugs, bioequivalence, drug dissolution, solubility, spectrophotometry, Therapeutics. Pharmacology, RM1-950, Pharmacy and materia medica, RS1-441
الوصف: Context: For regulatory reasons, a biowaiver is characterized as the substitution or exemption of bioavailability and/or bioequivalence research with in vitro dissolution tests, according to the Biopharmaceutical Classification System (BCS). These studies need validated quantification methods to give reliable results. Aims: To develop and validate the UV spectrophotometric method for biowaiver studies in pyrazinamide tablets. Methods: The parameters for validation, such as specificity, linearity, range, accuracy, precision, stability of the analytical solution, filter test, limits of detection, and quantification, were assessed according to the standards set by the guidelines of the International Conference on Harmonization and the United States Pharmacopeia. The dissolution operating conditions were 900 mL of dissolution media at pH 1.2, 4.5, and 6.8, with the paddle method at 75 rpm and sampling times of 5, 10, 15, 20, and 30 minutes. Results: The wavelength of maximum absorbance was 268 nm for the three dissolution media. The method was linear in the range of 1.11112–13.3334 µg/mL (r2>0.998). The limits of detection ranged from 0.0157 to 0.0222 µg/mL, and the limits of quantification were between 0.0415 and 0.0546 µg/mL. The recovered values were between 99.4 and 103.0%. No interference from the placebo was observed. The relative standard deviation values were less than 2% for precision. For robustness, different conditions were evaluated as wavelengths, changes in concentration, and Whatman No. 40, 41, and 42 filters; they did not modify the method response. The samples were kept unchanged for a period of 24 hours at 25°C. Conclusions: The UV spectrophotometric method was linear, accurate, specific, and precise in the concentration range studied and in the dissolution media at pH levels of 1.2, 4.5, and 6.8, being suitable for biowaiver studies in pyrazinamide tablets.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
Spanish; Castilian
تدمد: 0719-4250
Relation: https://jppres.com/jppres/pdf/vol12/jppres23.1846_12.3.539.pdf; https://doaj.org/toc/0719-4250
DOI: 10.56499/jppres23.1846_12.3.539
URL الوصول: https://doaj.org/article/f653e13f9df844069ef44027cdc520ef
رقم الأكسشن: edsdoj.f653e13f9df844069ef44027cdc520ef
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:07194250
DOI:10.56499/jppres23.1846_12.3.539