دورية أكاديمية
Feasibility of thin-slice abdominal CT in overweight patients using a vendor neutral image-based denoising algorithm: Assessment of image noise, contrast, and quality.
العنوان: | Feasibility of thin-slice abdominal CT in overweight patients using a vendor neutral image-based denoising algorithm: Assessment of image noise, contrast, and quality. |
---|---|
المؤلفون: | Akio Tamura, Manabu Nakayama, Yoshitaka Ota, Masayoshi Kamata, Yasuyuki Hirota, Misato Sone, Makoto Hamano, Ryoichi Tanaka, Kunihiro Yoshioka |
المصدر: | PLoS ONE, Vol 14, Iss 12, p e0226521 (2019) |
بيانات النشر: | Public Library of Science (PLoS), 2019. |
سنة النشر: | 2019 |
المجموعة: | LCC:Medicine LCC:Science |
مصطلحات موضوعية: | Medicine, Science |
الوصف: | The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1932-6203 |
Relation: | https://doaj.org/toc/1932-6203 |
DOI: | 10.1371/journal.pone.0226521 |
URL الوصول: | https://doaj.org/article/fc8e8ac0f7884317b8f7a692a7785583 |
رقم الأكسشن: | edsdoj.fc8e8ac0f7884317b8f7a692a7785583 |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 19326203 |
---|---|
DOI: | 10.1371/journal.pone.0226521 |