مورد إلكتروني

Comparison of mediastinal shift angles obtained with ultrasound and magnetic resonance imaging in fetuses with isolated left sided congenital diaphragmatic hernia

التفاصيل البيبلوغرافية
العنوان: Comparison of mediastinal shift angles obtained with ultrasound and magnetic resonance imaging in fetuses with isolated left sided congenital diaphragmatic hernia
المؤلفون: Romiti, A., Viggiano, M., Savelli, S., Salvi, Silvia, Vicario, R., Vassallo, Chiara, Valfre, L., Toma, P., Bonito, M., Lanzone, Antonio, Bagolan, P., Caforio, Leonardo, Salvi S. (ORCID:0000-0001-7793-9612), Vassallo C., Lanzone A. (ORCID:0000-0003-4119-414X), Caforio L. (ORCID:0000-0002-1677-695X)
بيانات النشر: Taylor and Francis Ltd 2022
نوع الوثيقة: Electronic Resource
مستخلص: Objectives: To compare ultrasound (US) and magnetic resonance imaging (MRI) in the assessment of mediastinal shift angles (MSAs) in fetuses affected by isolated left congenital diaphragmatic hernia (CDH). The use of MRI-MSA and US-MSA as prognostic factor for postnatal survival in fetal left CDH was also explored. Methods: This was an observational study of 29 fetuses with prenatally diagnosed isolated left CDH, assessed with both US and MRI examinations between January 2015 and December 2018. The US-MSA measurements performed within 2 weeks from the MRI assessment were considered for the analysis. The primary outcome was the postnatal survival rate. Results: No significant difference between US and MRI MSAs was detected (p =.419). Among the 29 cases, there were 21 alive infants, for an overall postnatal survival rate of 72.41%. After stratifying for postnatal survival, the best cutoffs with the highest discriminatory power in terms of sensibility and specificity were 42.1° for the US-MSA and 39.1° for the MRI-MSA. The performance of MRI-MSA in predicting postnatal survival was close to that of US-MSA in terms of sensitivity (62.5 versus 50.0%), specificity (80.9 versus 90.5%), positive predictive value (55.6 versus 66.7%), negative predictive value (85.0 versus 82.6%) and accuracy (75.9 versus 79.3%). There was no statistically significant difference between the two modalities (p >.05 for all). Conclusions: MRI and US can be interchangeably used for the assessment of MSA in prenatally diagnosed isolated left CDH. Moreover, MSA measured by both US and MRI was confirmed to be correlated with perinatal outcome in terms of survival.
مصطلحات الفهرس: Congenital diaphragmatic hernia, fetal ultrasound, magnetic resonance imaging, mediastinal shift angle, prenatal diagnosis, pulmonary hypoplasia, Settore MED/40 - GINECOLOGIA E OSTETRICIA, info:eu-repo/semantics/article
URL: http://hdl.handle.net/10807/167404
info:eu-repo/semantics/altIdentifier/pmid/31973612
info:eu-repo/semantics/altIdentifier/wos/WOS:000509014000001
volume:35
issue:2
firstpage:269
lastpage:274
numberofpages:6
issueyear:2020
journal:THE JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE
الإتاحة: Open access content. Open access content
ملاحظة: English
أرقام أخرى: SYC oai:publicatt.unicatt.it:10807/167404
10.1080/14767058.2020.1716714
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85078470226
1242037470
المصدر المساهم: UNIV CATTOLICA DEL SACRO CUORE
From OAIster®, provided by the OCLC Cooperative.
رقم الأكسشن: edsoai.on1242037470
قاعدة البيانات: OAIster