Intrapartum non-invasive electrophysiological monitoring: a prospective observational study

التفاصيل البيبلوغرافية
العنوان: Intrapartum non-invasive electrophysiological monitoring: a prospective observational study
المصدر: Acta Obstetricia et Gynecologica Scandinavica vol.99 (2020) nr.10 p.1387-1395 [ISSN 0001-6349]
بيانات النشر: 2020
تفاصيل مُضافة: Lempersz, Carlijn
Lempersz, Carlijn
Noben, Lore
van Osta, G.
Wassen, M.
Meershoek, A.
Bakker, P.
Jacquemyn, Y.
Cuerva, M.
Vullings, Rik
Westerhuis, Michelle E.M.H.
Oei, S.G. (Guid)
نوع الوثيقة: Electronic Resource
مستخلص: Introduction: Doppler ultrasound cardiotocography is a non-invasive alternative that, despite its poor specificity, is often first choice for intrapartum monitoring. Doppler ultrasound suffers from signal loss due to fetal movements and is negatively correlated with maternal body mass index (BMI). Reported accuracy of fetal heart rate monitoring by Doppler ultrasound varies between 10.6 and 14.3 bpm and reliability between 62.4% and 73%. The fetal scalp electrode (FSE) is considered the reference standard for fetal monitoring but can only be applied after membranes have ruptured with sufficient cervical dilatation and is sometimes contra-indicated. A non-invasive alternative that overcomes the shortcomings of Doppler ultrasound, providing reliable information on fetal heart rate, could be the answer. Non-invasive fetal electrocardiography (NI-fECG) uses a wireless electrode patch on the maternal abdomen to obtain both fetal and maternal heart rate signals as well as an electrohysterogram. We aimed to validate a wireless NI-fECG device for intrapartum monitoring in term singleton pregnancies, by comparison with the FSE. Material and methods: We performed a multicenter cross-sectional observational study at labor wards of 6 hospitals located in the Netherlands, Belgium, and Spain. Laboring women with a healthy singleton fetus in cephalic presentation and gestational age between 36 and 42 weeks were included. Participants received an abdominal electrode patch and FSE after written informed consent. Accuracy, reliability, and success rate of fetal heart rate readings were determined, using FSE as reference standard. Analysis was performed for the total population and measurement period as well as separated by labor stage and BMI class (≤30 and >30 kg/m 2). Results: We included a total of 125 women. Simultaneous registrations with NI-fECG and FSE were available in 103 women. Overall accuracy is −1.46 bpm and overall reliability 86.84%. Overall success ra
مصطلحات الفهرس: fetal monitoring, fetus, heart rate monitoring, labor, non-invasive fetal electrocardiography, Body Mass Index, Heart Rate, Fetal, Reproducibility of Results, Prospective Studies, Cross-Sectional Studies, Humans, Cardiotocography/instrumentation, Electrodes, Pregnancy, Wireless Technology, Adult, Female, Tijdschriftartikel, Article
URL: https://research.tue.nl/en/publications/09e05828-da9c-4180-8f45-09fbd368a7ae
https://pure.tue.nl/ws/files/149502072/F2_Manuscript_finalAuthorVersion.docx
https://pure.tue.nl/ws/files/149502072/F2_Manuscript_finalAuthorVersion.docx
الإتاحة: Open access content. Open access content
info:eu-repo/semantics/openAccess
ملاحظة: DOI: 10.1111/aogs.13873
Acta Obstetricia et Gynecologica Scandinavica vol.99 (2020) nr.10 p.1387-1395 [ISSN 0001-6349]
English
أرقام أخرى: NLTUR oai:pure.tue.nl:publications/09e05828-da9c-4180-8f45-09fbd368a7ae
https://research.tue.nl/en/publications/09e05828-da9c-4180-8f45-09fbd368a7ae
1250484387
المصدر المساهم: TU/E REPOSITORY
From OAIster®, provided by the OCLC Cooperative.
رقم الأكسشن: edsoai.on1250484387
قاعدة البيانات: OAIster