دورية أكاديمية

Evaluation of possible factors affecting contrast sensitivity function in patients with primary Sjögren’s syndrome

التفاصيل البيبلوغرافية
العنوان: Evaluation of possible factors affecting contrast sensitivity function in patients with primary Sjögren’s syndrome
المؤلفون: Arikan, Sedat, Gokmen, Ferhat, Comez, Arzu Taskiran, Gencer, Baran, Kara, Selcuk, Akbal, Ayla
المصدر: Arquivos Brasileiros de Oftalmologia. June 2015 78(3)
بيانات النشر: Conselho Brasileiro de Oftalmologia, 2015.
سنة النشر: 2015
مصطلحات موضوعية: Sjogren’s syndrome, Corneal wavefront aberration, Dry eye diseases, Optic disk/pathology, Optical coherence tomography
الوصف: Purpose: The contrast sensitivity (CS) function in patients with primary Sjögren’s syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Methods: Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. Results: The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). Conclusions: The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage.
نوع الوثيقة: article
وصف الملف: text/html
اللغة: English
تدمد: 0004-2749
DOI: 10.5935/0004-2749.20150039
URL الوصول: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492015000300004
حقوق: info:eu-repo/semantics/openAccess
رقم الأكسشن: edssci.S0004.27492015000300004
قاعدة البيانات: SciELO
الوصف
تدمد:00042749
DOI:10.5935/0004-2749.20150039