Accuracy of visual and image-based ICDAS criteria compared with a micro-CT gold standard for caries detection on occlusal surfaces

التفاصيل البيبلوغرافية
العنوان: Accuracy of visual and image-based ICDAS criteria compared with a micro-CT gold standard for caries detection on occlusal surfaces
المؤلفون: CARVALHO, Raquel Nogueira de, LETIERI, Aline dos Santos, VIEIRA, Thiago Isidro, SANTOS, Thais Maria Pires dos, LOPES, Ricardo Tadeu, NEVES, Aline de Almeida, POMARICO, Luciana
المصدر: Brazilian Oral Research. January 2018 32
بيانات النشر: Sociedade Brasileira de Pesquisa Odontológica - SBPqO, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Diagnostic Imaging, Dental Caries, Photography, Dental, X-Ray Microtomography
الوصف: The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman’s rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.
نوع الوثيقة: article
وصف الملف: text/html
اللغة: English
تدمد: 1806-8324
DOI: 10.1590/1807-3107bor-2018.vol32.0060
URL الوصول: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242018000100251
حقوق: info:eu-repo/semantics/openAccess
رقم الأكسشن: edssci.S1806.83242018000100251
قاعدة البيانات: SciELO
الوصف
تدمد:18068324
DOI:10.1590/1807-3107bor-2018.vol32.0060