دورية أكاديمية

Evaluation of the Stratus CS fluorometer for the determination of plasma myoglobin.

التفاصيل البيبلوغرافية
العنوان: Evaluation of the Stratus CS fluorometer for the determination of plasma myoglobin.
المؤلفون: Couck P; Laboratorium Klinische Chemie, Academisch Ziekenhuis Vrije Universiteit Brussel, Brussel, Belgie. pedro.couck@az.vub.ac.be, Claeys R, Vanderstraeten E, Gorus FK
المصدر: Acta clinica Belgica [Acta Clin Belg] 2005 Mar-Apr; Vol. 60 (2), pp. 75-8.
نوع المنشور: Comparative Study; Evaluation Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Taylor & Francis Country of Publication: England NLM ID: 0370306 Publication Model: Print Cited Medium: Print ISSN: 1784-3286 (Print) Linking ISSN: 17843286 NLM ISO Abbreviation: Acta Clin Belg Subsets: MEDLINE
أسماء مطبوعة: Publication: 2016- : Abingdon : Taylor & Francis
Original Publication: Bruxelles : Acta Clinica Belgica
مواضيع طبية MeSH: Coronary Disease/*blood , Fluorometry/*instrumentation , Immunoenzyme Techniques/*instrumentation , Myoglobin/*blood, Belgium ; Coronary Disease/diagnosis ; Equipment Design ; Equipment Safety ; Hematologic Tests/instrumentation ; Hematologic Tests/methods ; Humans ; Immunoenzyme Techniques/methods ; Myoglobin/analysis ; Sensitivity and Specificity
مستخلص: Circulating myoglobin is recognized as an early and sensitive marker of acute coronary diseases. Long turnaround time of myoglobin assays jeopardize their clinical utility. We evaluated the analytical performance of the Stratus CS fluorometric enzyme immunoassay based on dendrimer technology, and claimed to achieve a fast and reliable determination of plasma myoglobin concentrations. Precision complied with the recommended analytical performance criteria. Method comparison and recovery experiments indicated, that despite good between-method correlations, the Stratus CS method overestimated myoglobin concentrations in comparison with values obtained on Cobas Integra 400 and BN A. However, since the manufacturers' cut-off for elevated plasma myoglobin levels was higher for Stratus CS than for other techniques, few discrepant results were observed between methods. Elevated levels of hemoglobin, triglycerides and rheumatoid factors did not interfere in the Stratus CS method but hyperbilirubinemia caused a positive difference.
المشرفين على المادة: 0 (Myoglobin)
تواريخ الأحداث: Date Created: 20050809 Date Completed: 20050902 Latest Revision: 20191210
رمز التحديث: 20221213
DOI: 10.1179/acb.2005.014
PMID: 16082992
قاعدة البيانات: MEDLINE
الوصف
تدمد:1784-3286
DOI:10.1179/acb.2005.014