دورية أكاديمية

[Abnormal head position caused by incorrect prescription for astigmatism: case report].

التفاصيل البيبلوغرافية
العنوان: [Abnormal head position caused by incorrect prescription for astigmatism: case report].
عنوان ترانسليتريتد: Posição viciosa de cabeça por astigmatismo mal corrigido: relato de caso.
المؤلفون: Castro FA; Departamento de Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, Hospital das Clínicas, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP., Simão ML, Abbud CM, Foschini RM, Bicas HE
المصدر: Arquivos brasileiros de oftalmologia [Arq Bras Oftalmol] 2005 Sep-Oct; Vol. 68 (5), pp. 687-91. Date of Electronic Publication: 2005 Nov 28.
نوع المنشور: Case Reports; English Abstract; Journal Article
اللغة: Portuguese
بيانات الدورية: Publisher: Conselho Brasileiro de Oftalmologia Country of Publication: Brazil NLM ID: 0400645 Publication Model: Print-Electronic Cited Medium: Print ISSN: 0004-2749 (Print) Linking ISSN: 00042749 NLM ISO Abbreviation: Arq Bras Oftalmol Subsets: MEDLINE
أسماء مطبوعة: Publication: São Paulo : Conselho Brasileiro de Oftalmologia
Original Publication: São Paulo.
مواضيع طبية MeSH: Head* , Posture*, Astigmatism/*rehabilitation, Child ; Diagnostic Errors/adverse effects ; Diagnostic Techniques, Ophthalmological ; Female ; Head Movements ; Humans ; Lenses ; Visual Acuity
مستخلص: Abnormal head position is a compensatory condition which improves patients' vision. It can be caused by ophthalmological problems such as oculomotor imbalances (strabismus, nystagmus) and high astigmatism. However, it results in esthetic impairment, orthopedic trouble and facial asymmetries. We describe a case of a girl, JL, 8 years, with abnormal head position tilted to the left since the last glasses were prescribed. The correction used by the patient was: right eye = +2.00 sph diopter -5.5 cyl 180 degrees and left eye = +2.25 sph diopter -5.75 cyl 180 degrees. In tilted position, the correct visual acuity was: right eye 6/12 and left eye 6/9. No deviations were noted by the cover test and the remaining ophthalmological examination was completely normal. Retinoscopy under cycloplegia and subjective test showed right eye = +3.50 sph diopter -6.00 cyl 10 degrees; and left eye = +3.50 sph diopter -6.00 cyl 170 degrees, with visual acuity 6/6 in both eyes. With adequate prescription, the head position was normalized. Wrong cylindrical positions for correction of high astigmatism may cause abnormal head position. Retinoscopy under cycloplegia and subjective test are essential for precise diagnoses and prescriptions.
تواريخ الأحداث: Date Created: 20051203 Date Completed: 20060626 Latest Revision: 20190922
رمز التحديث: 20231215
DOI: 10.1590/s0004-27492005000500022
PMID: 16322871
قاعدة البيانات: MEDLINE
الوصف
تدمد:0004-2749
DOI:10.1590/s0004-27492005000500022