دورية أكاديمية
Bi-ventricular circulatory support with the Abiomed AB5000 system in a patient with idiopathic refractory ventricular fibrillation.
العنوان: | Bi-ventricular circulatory support with the Abiomed AB5000 system in a patient with idiopathic refractory ventricular fibrillation. |
---|---|
المؤلفون: | Zhang L; Section of Cardiac Surgery, Department of Surgery, Washington Hospital Center, Washington, DC 20010-2975, USA. li.zhang@medstar.net, Kapetanakis EI, Cooke RH, Sweet LC, Boyce SW |
المصدر: | The Annals of thoracic surgery [Ann Thorac Surg] 2007 Jan; Vol. 83 (1), pp. 298-300. |
نوع المنشور: | Case Reports; Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Country of Publication: Netherlands NLM ID: 15030100R Publication Model: Print Cited Medium: Internet ISSN: 1552-6259 (Electronic) Linking ISSN: 00034975 NLM ISO Abbreviation: Ann Thorac Surg Subsets: MEDLINE |
أسماء مطبوعة: | Publication: Amsterdam : Elsevier Original Publication: Boston. |
مواضيع طبية MeSH: | Heart-Assist Devices*, Ventricular Fibrillation/*surgery, Humans ; Male ; Middle Aged ; Ventricular Fibrillation/physiopathology |
مستخلص: | A 45-year-old man had life-threatening recurrent idiopathic ventricular fibrillation and persistent cardiogenic shock develop. The episodes of ventricular fibrillation were refractory to aggressive medical management; therefore an Abiomed AB5000 bi-ventricular support system was implanted for arrhythmia control. The device was able to maintain hemodynamic stability during the following 2 weeks. The patient was discharged from the hospital with fully recovered cardiac function. |
تواريخ الأحداث: | Date Created: 20061223 Date Completed: 20070104 Latest Revision: 20061222 |
رمز التحديث: | 20231215 |
DOI: | 10.1016/j.athoracsur.2006.05.034 |
PMID: | 17184687 |
قاعدة البيانات: | MEDLINE |
تدمد: | 1552-6259 |
---|---|
DOI: | 10.1016/j.athoracsur.2006.05.034 |