دورية أكاديمية

Effectiveness of the Amplatzer device for transcatheter closure of an ostium secundum atrial septal defect.

التفاصيل البيبلوغرافية
العنوان: Effectiveness of the Amplatzer device for transcatheter closure of an ostium secundum atrial septal defect.
المؤلفون: Cardoso CO; Programa de Pôs-graduaçúo, Instituto de Cardiologia do Rio Grande do Sul, Fundaçúo Universitária de Cardiologia, Porto Alegre, RS, Brazil., Rossi Filho RI, Machado PR, François LM, Horowitz ES, Sarmento-Leite R
المصدر: Arquivos brasileiros de cardiologia [Arq Bras Cardiol] 2007 Apr; Vol. 88 (4), pp. 384-9.
نوع المنشور: Evaluation Study; Journal Article
اللغة: English; Portuguese
بيانات الدورية: Publisher: Sociedad Brasileira De Cardiologia Country of Publication: Brazil NLM ID: 0421031 Publication Model: Print Cited Medium: Internet ISSN: 1678-4170 (Electronic) Linking ISSN: 0066782X NLM ISO Abbreviation: Arq Bras Cardiol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Sao Paulo : Sociedad Brasileira De Cardiologia
مواضيع طبية MeSH: Cardiac Catheterization/*instrumentation , Heart Septal Defects, Atrial/*therapy, Adult ; Cardiac Catheterization/methods ; Cohort Studies ; Disease-Free Survival ; Echocardiography, Transesophageal ; Female ; Heart Septal Defects, Atrial/diagnostic imaging ; Humans ; Kaplan-Meier Estimate ; Male ; Prostheses and Implants ; Retrospective Studies ; Treatment Outcome
مستخلص: Objective: To evaluate the effectiveness of the Amplatzer septal occluder in the treatment of ostium secundum atrial septal defects (OS ASDs).
Methods: Retrospective cohort study conducted between November 1998 and September 2005 involving 101 OS ASD transcatheter occlusion procedures in our institution. All procedures were conducted in the hemodynamic laboratory under general anesthesia with transoesophageal echocardiographic monitoring (TEE). Clinical and echocardiography assessments of the patients were conducted at 30 days, six months and on an annual basis. The results are presented as averages, standard deviations and percentages. Event-free survival was estimated using the Kaplan-Meier curve.
Results: From the 101 patients, 60 (59.4%) were females. Mean age, weight, height, body mass index and body surface area were, respectively: 24.3 +/- 18.31 years, 51.88 +/- 23.76 kg, 140.59 +/- 39.3 cm, 23.18 +/- 18.9 kg/m(2) and 1.24 +/- 0.21 m(2). The prevalence of interatrial septum aneurysms was 4.95%, and 98 cases had an isolated defect. ASD diameters were 21.47 +/- 6.96 mm using an angiography and 21.22 +/- 7.93 mm using a TEE. The average size of the implanted devices was 23.92 +/- 7.25 mm, ranging from 9 mm to 40 mm. The procedure time was 90.47 +/- 26.67 minutes and the average hospital stay was 2.51 +/- 0.62 days. Clinical and echocardiography follow-up was conducted at 12.81 +/- 8.41 months and all devices were securely anchored without any residual shunts. The procedure success rate was 93% (94/101). In five cases adequate deployment of the device was not possible and 2 patients presented residual ASD. No major complications occurred.
Conclusion: The Amplatzer septal occluder is an effective OS ASD transcatheter treatment device.
تواريخ الأحداث: Date Created: 20070605 Date Completed: 20080422 Latest Revision: 20191210
رمز التحديث: 20221213
DOI: 10.1590/s0066-782x2007000400003
PMID: 17546265
قاعدة البيانات: MEDLINE
الوصف
تدمد:1678-4170
DOI:10.1590/s0066-782x2007000400003