دورية أكاديمية

Ten-year results of the Press Fit Condylar Sigma total knee replacement.

التفاصيل البيبلوغرافية
العنوان: Ten-year results of the Press Fit Condylar Sigma total knee replacement.
المؤلفون: Arthur CH; Victoria Hospital Kirkcaldy, Kirkcaldy, UK. calumarthur@doctors.org.uk, Wood AM, Keenan AC, Clayton RA, Walmsley P, Brenkel I
المصدر: The bone & joint journal [Bone Joint J] 2013 Feb; Vol. 95-B (2), pp. 177-80.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: British Editorial Society of Bone & Joint Surgery Country of Publication: England NLM ID: 101599229 Publication Model: Print Cited Medium: Internet ISSN: 2049-4408 (Electronic) Linking ISSN: 20494394 NLM ISO Abbreviation: Bone Joint J Subsets: MEDLINE
أسماء مطبوعة: Original Publication: London : British Editorial Society of Bone & Joint Surgery
مواضيع طبية MeSH: Arthroplasty, Replacement, Knee/*methods , Knee Joint/*surgery , Knee Prosthesis/*adverse effects, Adult ; Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee/adverse effects ; Arthroplasty, Replacement, Knee/mortality ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Prospective Studies ; Reoperation ; Survival Rate ; Treatment Outcome
مستخلص: We report ten-year clinical and radiological follow-up data for the Sigma Press Fit Condylar total knee replacement system (Sigma PFC TKR). Between October 1998 and October 1999 a total of 235 consecutive PFC Sigma TKRs were carried out in 203 patients. Patients were seen at a specialist nurse-led clinic seven to ten days before admission and at six and 18 months, three, five and eight to ten years after surgery. Data were recorded prospectively at each clinic visit. Radiographs were obtained at the five- and eight- to ten-year follow-up appointments. Of the 203 patients, 147 (171 knees) were alive at ten years and 12 were lost to follow-up. A total of eight knees (3.4%) were revised, five for infection and three to change the polyethylene insert. The survival at ten years with an endpoint of revision for any reason was 95.9%, and with an endpoint of revision for aseptic failure was 98.7%. The mean American Knee Society Score (AKSS) was 79 (10 to 99) at eight to ten years, compared with 31 (2 to 62) pre-operatively. Of 109 knee with radiographs reviewed, 47 knees had radiolucent lines but none showed evidence of loosening.
تواريخ الأحداث: Date Created: 20130201 Date Completed: 20130404 Latest Revision: 20160525
رمز التحديث: 20231215
DOI: 10.1302/0301-620X.95B2.29695
PMID: 23365025
قاعدة البيانات: MEDLINE
الوصف
تدمد:2049-4408
DOI:10.1302/0301-620X.95B2.29695