دورية أكاديمية

Dynamic contrast-enhanced magnetic resonance imaging assessment of kidney function and renal masses: single slice versus whole organ/tumor.

التفاصيل البيبلوغرافية
العنوان: Dynamic contrast-enhanced magnetic resonance imaging assessment of kidney function and renal masses: single slice versus whole organ/tumor.
المؤلفون: Winter KS; From the *Institute for Clinical Radiology, †Josef-Lissner Institute for Biomedical Imaging, Institute for Clinical Radiology, and ‡Department of Urology, University Hospitals Munich, Munich; and §Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany., Helck AD, Ingrisch M, Staehler M, Stief C, Sommer WH, Braunagel M, Kazmierczak PM, Reiser MF, Nikolaou K, Notohamiprodjo M
المصدر: Investigative radiology [Invest Radiol] 2014 Nov; Vol. 49 (11), pp. 720-7.
نوع المنشور: Comparative Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Lippincott Williams & Wilkins Country of Publication: United States NLM ID: 0045377 Publication Model: Print Cited Medium: Internet ISSN: 1536-0210 (Electronic) Linking ISSN: 00209996 NLM ISO Abbreviation: Invest Radiol Subsets: MEDLINE
أسماء مطبوعة: Publication: 1998- : Hagerstown, MD : Lippincott Williams & Wilkins
Original Publication: Philadelphia.
مواضيع طبية MeSH: Contrast Media*, Carcinoma, Renal Cell/*diagnosis , Image Enhancement/*methods , Image Interpretation, Computer-Assisted/*methods , Kidney Neoplasms/*diagnosis , Magnetic Resonance Imaging/*methods, Female ; Glomerular Filtration Rate ; Humans ; Image Processing, Computer-Assisted/methods ; Imaging, Three-Dimensional/methods ; Kidney/pathology ; Kidney Diseases/diagnosis ; Male ; Middle Aged ; Prospective Studies ; Sensitivity and Specificity
مستخلص: Objectives: The aim of this study was to compare single-slice and 3-dimensional (3D) analysis for magnetic resonance renography (plasma flow [FP], plasma volume [VP], and glomerular filtration rate [GFR]) and for dynamic contrast-enhanced magnetic resonance imaging (MRI) of renal tumors (FP, VP, permeability-surface area product), respectively.
Material and Methods: We prospectively included 22 patients (43 kidneys with 22 suspicious renal lesions) and performed preoperative and postoperative imaging before and after partial nephrectomy, respectively. Of the 22 renal lesions, 15 turned out to be renal cell carcinoma and were included in the tumor analysis, altogether leading to 86 renal and 15 tumor MRI scans, respectively. Dynamic contrast-enhanced MRI was performed with a time-resolved angiography with stochastic trajectories sequence (spatial resolution, 2.6 × 2.6 × 2.6 mm3; temporal resolution, 2.5 seconds) at 3 T (Magnetom Verio; Siemens Healthcare Sector) after injection of 0.05 mmol/kg body weight Gadobutrol (Bayer Healthcare Pharmaceuticals). Analysis was performed using regions of interest encompassing a single central slice and the whole kidney/tumor, respectively. A 2-compartment model yielding FP, VP, GFR, or tumor permeability-surface area product was used for kinetic modelling. Modelling was performed based on relative contrast enhancement to account for coil-related inhomogeneity. Significance in difference, agreement, and goodness of fit of the data to the curve was assessed with paired t tests, Bland-Altman plots, and χ2 test, respectively.
Results: Bland-Altman analysis revealed a good agreement between both types of measurement for kidneys and tumors, respectively. Results between single-slice and whole-kidney regions of interest showed significant differences for Fp (single slice, 256.1 ± 104.1 mL/100 mL/min; whole kidney, 217.2 ± 92.5 mL/100 mL/min; P < 0.01). Regarding VP and GFR, no significant differences were observed. The χ2 test showed a significantly better goodness of fit of the data to the curve for whole kidneys (0.30% ± 0.18%) than for single slices (0.43% ± 0.26%) (P < 0.01). In contrast to renal assessment, tumor analysis showed no significant differences regarding functional parameters and χ test, respectively.
Conclusion: In dynamic contrast-enhanced MRI of the kidney, both 3D whole-organ/tumor and single-slice analyses provide roughly comparable values in functional analysis. However, 3D assessment is considerably more precise and should be preferred if available.
المشرفين على المادة: 0 (Contrast Media)
تواريخ الأحداث: Date Created: 20140606 Date Completed: 20150615 Latest Revision: 20151119
رمز التحديث: 20231215
DOI: 10.1097/RLI.0000000000000075
PMID: 24901546
قاعدة البيانات: MEDLINE
الوصف
تدمد:1536-0210
DOI:10.1097/RLI.0000000000000075