دورية أكاديمية

Single line-of-sight dual energy backlighter for mix width experiments.

التفاصيل البيبلوغرافية
العنوان: Single line-of-sight dual energy backlighter for mix width experiments.
المؤلفون: Baker KL; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Glendinning SG; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Guymer TM; AWE, Aldermaston, Reading, Berkshire RG7 4PR, United Kingdom., Martinez D; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Moore AS; AWE, Aldermaston, Reading, Berkshire RG7 4PR, United Kingdom., Dittrich TR; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., MacLaren SA; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Felker S; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Seugling R; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Doane D; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Wallace R; Lawrence Livermore National Laboratory, Livermore, California 94551, USA., Whiting N; Laboratory for Laser Energetics, Rochester, New York 14627, USA., Sorce C; Laboratory for Laser Energetics, Rochester, New York 14627, USA.
المصدر: The Review of scientific instruments [Rev Sci Instrum] 2014 Nov; Vol. 85 (11), pp. 11D621.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: American Institute Of Physics Country of Publication: United States NLM ID: 0405571 Publication Model: Print Cited Medium: Internet ISSN: 1089-7623 (Electronic) Linking ISSN: 00346748 NLM ISO Abbreviation: Rev Sci Instrum Subsets: PubMed not MEDLINE
أسماء مطبوعة: Publication: 1933- : Woodbury, N.Y. : American Institute Of Physics
Original Publication: 1930-1932 : Menasha, WI : Optical Society of America
مستخلص: We present a diagnostic technique used to spatially multiplex two x-ray radiographs of an object onto a detector along a single line-of-sight. This technique uses a thin, <2 μm, cosputtered backlighter target to simultaneously produce both Ni and Zn Heα emission. A Ni picket fence filter, 500 μm wide bars and troughs, is then placed in front of the detector to pass only the Ni Heα emission in the bar region and both energies in the trough region thereby spatially multiplexing the two radiographs on a single image. Initial experimental results testing the backlighter spectrum are presented along with simulated images showing the calculated radiographic images though the nickel picket fence filter which are used to measure the mix width in an accelerated nickel foam.
تواريخ الأحداث: Date Created: 20141129 Date Completed: 20150513 Latest Revision: 20141128
رمز التحديث: 20231215
DOI: 10.1063/1.4893005
PMID: 25430197
قاعدة البيانات: MEDLINE
الوصف
تدمد:1089-7623
DOI:10.1063/1.4893005