دورية أكاديمية

Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis.

التفاصيل البيبلوغرافية
العنوان: Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis.
المؤلفون: Schotanus MG; Medical Researcher at Zuyderland Medical Centre, Dr H vd Hoffplein 1, 6162 AG, Sittard-Geleen, The Netherlands. m.schotanus@orbisconcern.nl., van Haaren EH; Orthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. em.vanhaaren@orbisconcern.nl., Hendrickx RP; Orthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. r.hendrickx@orbisconcern.nl., Jansen EJ; Orthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. ed.jansen@orbisconcern.nl., Kort NP; Orthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. n.kort@orbisconcern.nl.
المصدر: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2015 Dec; Vol. 25 (8), pp. 1313-20. Date of Electronic Publication: 2015 Aug 12.
نوع المنشور: Evaluation Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Springer-Verlag France Country of Publication: France NLM ID: 9518037 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1432-1068 (Electronic) Linking ISSN: 16338065 NLM ISO Abbreviation: Eur J Orthop Surg Traumatol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Paris : Springer-Verlag France
مواضيع طبية MeSH: Arthroplasty, Replacement, Knee/*methods , Knee Injuries/*complications , Osteoarthritis, Knee/*surgery, Aged ; Blood Loss, Surgical ; Female ; Fracture Fixation, Intramedullary/methods ; Humans ; Knee Prosthesis ; Male ; Middle Aged ; Operative Time ; Osteoarthritis, Knee/diagnostic imaging ; Osteoarthritis, Knee/etiology ; Patient Outcome Assessment ; Preoperative Care/methods ; Prospective Studies ; Radiography, Interventional/methods ; Sensitivity and Specificity ; Tomography, X-Ray Computed/standards ; Treatment Outcome
مستخلص: Published clinical trials who studied the accuracy of patient-specific guides (PSG) for total knee arthroplasty exclude patients with articular deformity of the knee joint. We prospectively analysed a series of 30 patients with post-traumatic osteoarthritis of the knee joint with use of PSG. At 1 year post-operative, the achieved biomechanical (HKA) axis and varus/valgus of the femur and tibia components were measured on anterior-posterior (AP) long-standing weight-bearing radiographs. Flexion/extension of the femoral and AP slope of the tibia component was measured on standard lateral radiographs. Percentages >3° deviation of the pre-operative planned HKA axis and individual implant components were considered as outliers. Approved and used implant size, median blood loss (ml) and operation time (min) were obtained from the operation records. Pre- and 1-year post-operative patient-reported outcome measures (PROMs) were performed. Eighty-three per cent of the patients had a HKA axis restored <3° of the pre-operative planned alignment. Varus/valgus outliers were 0.0 and 6.7 % for the femoral and tibial components, respectively. Percentages of outliers of flexion/extension were 36.7 % for the femoral component and 10.0 % for the AP slope of the tibial component. Median blood loss was 300 ml (50-700), while operation time was 67 min (44-144). In 20 % of all cases, the approved implant size was changed into one size smaller. One-year post-operative PROMs improved significantly. We conclude that the accuracy of CT-based PSG is not impaired in patients with post-traumatic osteoarthritis and this modality can restore biomechanical limb alignment.
References: Clin Orthop Relat Res. 2013 Dec;471(12 ):3988-95. (PMID: 23907610)
Knee Surg Sports Traumatol Arthrosc. 2012 Mar;20(3):546-51. (PMID: 21800169)
Knee. 2013 Dec;20(6):407-11. (PMID: 23899651)
J Arthroplasty. 2006 Feb;21(2):284-8. (PMID: 16520220)
Acta Orthop. 2013 Apr;84(2):165-9. (PMID: 23496649)
J Bone Joint Surg Br. 2004 Jul;86(5):682-7. (PMID: 15274263)
Knee Surg Sports Traumatol Arthrosc. 2012 Jul;20(7):1307-22. (PMID: 21732057)
Clin Orthop Relat Res. 2012 Jan;470(1):45-53. (PMID: 21656315)
Chin Med J (Engl). 2010 Nov;123(21):2967-8. (PMID: 21162938)
J Arthroplasty. 2009 Dec;24(8):1164-9.e1. (PMID: 19577897)
Int Orthop. 2012 Jul;36(7):1379-85. (PMID: 22252414)
J Arthroplasty. 2014 Feb;29(2):343-7. (PMID: 23993343)
Orthopedics. 2012 Oct;35(10 Suppl):34-9. (PMID: 23026250)
J Arthroplasty. 2003 Apr;18(3 Suppl 1):23-6. (PMID: 12730923)
R I Med J (2013). 2013 Mar 01;96(3):34-7. (PMID: 23641437)
Kaohsiung J Med Sci. 2014 Aug;30(8):415-21. (PMID: 25002380)
Knee Surg Relat Res. 2013 Dec;25(4):194-201. (PMID: 24368997)
Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10 ):2200-5. (PMID: 23942882)
J Arthroplasty. 2009 Sep;24(6 Suppl):39-43. (PMID: 19553073)
Biomed Tech (Berl). 2012 Aug;57(4):301-6. (PMID: 22752760)
J Arthroplasty. 2013 Sep;28(8 Suppl):96-100. (PMID: 23910821)
Chin J Traumatol. 2005 Aug;8(4):195-9. (PMID: 16042863)
Knee. 2014 Mar;21(2):406-9. (PMID: 24378337)
Int J Med Robot. 2008 Sep;4(3):224-31. (PMID: 18680138)
J Oral Maxillofac Surg. 2005 Jul;63(7):1006-15. (PMID: 16003630)
Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10 ):2206-12. (PMID: 23928929)
Knee. 2003 Mar;10 (1):55-60. (PMID: 12649028)
Orthopedics. 2008 Sep;31(9):927-30. (PMID: 18814618)
Clin Orthop Surg. 2011 Mar;3(1):77-80. (PMID: 21369482)
Acta Orthop. 2014 Sep;85(5):480-7. (PMID: 25036719)
Clin Orthop Relat Res. 2013 Jan;471(1):169-74. (PMID: 22956239)
Case Rep Orthop. 2013;2013:174384. (PMID: 24191210)
فهرسة مساهمة: Keywords: CT-based; Knee alignment; Patient-specific guides; Post-traumatic osteoarthritis; Retained metal hardware; Total knee arthroplasty
تواريخ الأحداث: Date Created: 20150813 Date Completed: 20160831 Latest Revision: 20191210
رمز التحديث: 20221213
DOI: 10.1007/s00590-015-1677-3
PMID: 26265403
قاعدة البيانات: MEDLINE
الوصف
تدمد:1432-1068
DOI:10.1007/s00590-015-1677-3