دورية أكاديمية

Z-score-based semi-quantitative analysis of the volume of the temporal horn of the lateral ventricle on brain CT images.

التفاصيل البيبلوغرافية
العنوان: Z-score-based semi-quantitative analysis of the volume of the temporal horn of the lateral ventricle on brain CT images.
المؤلفون: Takahashi N; Department of Radiology and Nuclear Medicine, Research Institute for Brain and Blood Vessels-Akita, 6-10, Sensyukubota-machi,, Akita, Akita, 010-0874, Japan. takahashi-noriyuki@akita-noken.jp., Kinoshita T; Department of Radiology and Nuclear Medicine, Research Institute for Brain and Blood Vessels-Akita, 6-10, Sensyukubota-machi,, Akita, Akita, 010-0874, Japan., Ohmura T; Department of Radiology and Nuclear Medicine, Research Institute for Brain and Blood Vessels-Akita, 6-10, Sensyukubota-machi,, Akita, Akita, 010-0874, Japan., Lee Y; Department of Radiological Technology, School of Health Sciences, Niigata University, 2-746, Asahimachi-dori, Chuou-ku, Niigata, Niigata, 951-8518, Japan., Matsuyama E; Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, 6-22, Misaki-machi, Ohmuta, Hukuoka, 836-8505, Japan., Toyoshima H; Department of Radiology and Nuclear Medicine, Research Institute for Brain and Blood Vessels-Akita, 6-10, Sensyukubota-machi,, Akita, Akita, 010-0874, Japan., Tsai DY; Department of Electrical and Computer Engineering, National Institute of Technology,, Gifu College, 2236-2, kamimakuwa, Motosu-city, Gihu, 501-0495, Japan.
المصدر: Radiological physics and technology [Radiol Phys Technol] 2016 Jan; Vol. 9 (1), pp. 69-76. Date of Electronic Publication: 2015 Sep 24.
نوع المنشور: Journal Article; Research Support, Non-U.S. Gov't
اللغة: English
بيانات الدورية: Publisher: Springer Japan Country of Publication: Japan NLM ID: 101467995 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1865-0341 (Electronic) Linking ISSN: 18650333 NLM ISO Abbreviation: Radiol Phys Technol Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Tokyo : Springer Japan
مواضيع طبية MeSH: Cerebral Ventriculography* , Tomography, X-Ray Computed*, Lateral Ventricles/*anatomy & histology , Lateral Ventricles/*diagnostic imaging, Adult ; Aged ; Aged, 80 and over ; Female ; Humans ; Male ; Middle Aged ; Organ Size
مستخلص: The volume of the temporal horn of the lateral ventricle (THLV) on brain computed tomography (CT) images is important for neurologic diagnosis. Our purpose in this study was to develop a z-score-based semi-quantitative analysis for estimation of the THLV volume by using voxel-based morphometry. The THLV volume was estimated by use of a z-score mapping method that consisted of four main steps: anatomic standardization, construction of a normal reference database, calculation of the z score, and calculation of the mean z score in a volume of interest (VOI). A mean z score of the CT value obtained from a VOI around the THLV was used as an index for the THLV volume. CT scans from 50 subjects were evaluated. For evaluation of the accuracy of this method for estimating the THLV volume, the THLV volume was determined manually by neuroradiologists (serving as the reference volume). A mean z score was calculated from the VOI for each THLV of the 50 subjects by use of the proposed method. The accuracy of this method was evaluated by use of the relationship between the mean z score and the reference volume. The quadratic polynomial regression equation demonstrated a statistically significant correlation between the mean z score and the reference volume of the THLV (R (2) = 0.94; P < 0.0001). In 92 of 100 THLVs (92 %), the 95 % prediction interval of the regional mean z score captured the reference volume of the THLV. The z-score-based semi-quantitative analysis has the potential quantitatively to estimate the THLV volume on CT images.
References: Neuroinformatics. 2012 Apr;10 (2):159-72. (PMID: 22125015)
Neuroradiology. 1992;34(3):207-9. (PMID: 1630611)
AJNR Am J Neuroradiol. 2002 Jan;23(1):35-47. (PMID: 11827874)
J Neurol Neurosurg Psychiatry. 1998 Oct;65(4):590-3. (PMID: 9771795)
Acad Radiol. 2010 Nov;17 (11):1350-8. (PMID: 20634108)
AJNR Am J Neuroradiol. 2006 Aug;27(7):1454-8. (PMID: 16908557)
Neurology. 1998 Oct;51(4):993-9. (PMID: 9781519)
Magn Reson Med. 2008 Feb;59(2):260-7. (PMID: 18228600)
Int J Geriatr Psychiatry. 2004 Jun;19(6):570-4. (PMID: 15211538)
Eur J Radiol. 2008 May;66(2):268-73. (PMID: 17643890)
J Comput Assist Tomogr. 2010 Sep-Oct;34(5):751-6. (PMID: 20861780)
Neurology. 1990 Jun;40(6):872-83. (PMID: 2189080)
Hum Brain Mapp. 1999;7(4):254-66. (PMID: 10408769)
Psychiatry Res. 1995 Jul 28;57(2):119-30. (PMID: 7480379)
Acta Radiol. 1992 Jul;33(4):333-7. (PMID: 1633043)
Acad Radiol. 2010 Jan;17 (1):84-92. (PMID: 19734066)
Acad Radiol. 2010 Jun;17(6):718-26. (PMID: 20457415)
Acta Radiol. 2008 Feb;49(1):91-7. (PMID: 18210318)
فهرسة مساهمة: Keywords: Computed tomography; Temporal horn; Voxel-based morphometry; Z score; Z-score mapping
تواريخ الأحداث: Date Created: 20150926 Date Completed: 20161019 Latest Revision: 20181113
رمز التحديث: 20231215
DOI: 10.1007/s12194-015-0335-0
PMID: 26404397
قاعدة البيانات: MEDLINE
الوصف
تدمد:1865-0341
DOI:10.1007/s12194-015-0335-0