دورية أكاديمية

Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

التفاصيل البيبلوغرافية
العنوان: Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.
المؤلفون: Kwok IH; Colchester General Hospital, Turner Road, Colchester, Essex, CO4 5JL, United Kingdom. Electronic address: iriskwokhy@hotmail.com., Pallett SJ; Colchester General Hospital, Turner Road, Colchester, Essex, CO4 5JL, United Kingdom., Massa E; Colchester General Hospital, Turner Road, Colchester, Essex, CO4 5JL, United Kingdom., Cundall-Curry D; Colchester General Hospital, Turner Road, Colchester, Essex, CO4 5JL, United Kingdom., Loeffler MD; Colchester General Hospital, Turner Road, Colchester, Essex, CO4 5JL, United Kingdom.
المصدر: Injury [Injury] 2016 Mar; Vol. 47 (3), pp. 733-6. Date of Electronic Publication: 2015 Dec 31.
نوع المنشور: Evaluation Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Elsevier Country of Publication: Netherlands NLM ID: 0226040 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1879-0267 (Electronic) Linking ISSN: 00201383 NLM ISO Abbreviation: Injury Subsets: MEDLINE
أسماء مطبوعة: Publication: <2002->: Amsterdam : Elsevier
Original Publication: Bristol, Wright.
مواضيع طبية MeSH: Hemiarthroplasty*/methods , Preoperative Care* , Radiography*, Acetabulum/*diagnostic imaging , Femoral Neck Fractures/*diagnostic imaging , Hip Joint/*diagnostic imaging , Leg Length Inequality/*surgery, Acetabulum/anatomy & histology ; Acetabulum/surgery ; Aged ; Aged, 80 and over ; Female ; Femoral Neck Fractures/surgery ; Hip Joint/anatomy & histology ; Hip Joint/surgery ; Hip Prosthesis ; Humans ; Leg Length Inequality/diagnosis ; Male ; Middle Aged ; Prosthesis Design ; Prosthesis Fitting ; Radiographic Image Enhancement ; Reproducibility of Results ; Retrospective Studies
مستخلص: Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty.
(Copyright © 2016 Elsevier Ltd. All rights reserved.)
فهرسة مساهمة: Keywords: Femoral neck; Fractures; Hemiarthroplasty; Hip; Templating
تواريخ الأحداث: Date Created: 20160123 Date Completed: 20170518 Latest Revision: 20220331
رمز التحديث: 20231215
DOI: 10.1016/j.injury.2015.12.027
PMID: 26797019
قاعدة البيانات: MEDLINE
الوصف
تدمد:1879-0267
DOI:10.1016/j.injury.2015.12.027