MECHANICAL STUDY ON DORSAL STABILITY OF INTRAMEDULLARY OSTEOSYNTHESIS ASSOCIATED WITH EXTERNAL FIXATION (ULSON'S METHOD).
العنوان: | MECHANICAL STUDY ON DORSAL STABILITY OF INTRAMEDULLARY OSTEOSYNTHESIS ASSOCIATED WITH EXTERNAL FIXATION (ULSON'S METHOD). |
---|---|
المؤلفون: | Sardenberg T; Professor, Botucatu School of Medicine - UNESP - Botucatu, SP, Brazil., Muller SS; Professor, Botucatu School of Medicine - UNESP - Botucatu, SP, Brazil., Medeiros DR; Physician; Former Resident in Orthopedics and Traumatology of the Botucatu School of Medicine - UNESP - Botucatu, SP, Brazil., Baptistão PL; Physician; Former Resident in Orthopedics and Traumatology of the Botucatu School of Medicine - UNESP - Botucatu, SP, Brazil. |
المصدر: | Revista brasileira de ortopedia [Rev Bras Ortop] 2015 Nov 16; Vol. 46 (6), pp. 656-9. Date of Electronic Publication: 2015 Nov 16 (Print Publication: 2011). |
نوع المنشور: | Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Ltda Country of Publication: Brazil NLM ID: 101660959 Publication Model: eCollection Cited Medium: Print ISSN: 2255-4971 (Print) Linking ISSN: 22554971 NLM ISO Abbreviation: Rev Bras Ortop Subsets: PubMed not MEDLINE |
أسماء مطبوعة: | Original Publication: Rio de Janeiro : Elsevier Ltda, [2009]-[2018] |
مستخلص: | Objective: To evaluate the Ulson intramedullary fixation method, with external fixation in which the level of the external locking of the Kirschner wires is varied, and without external fixation. Methods: Eighteen porcine tibias were used. Transverse osteotomy was performed in the region of the tuberosity, and two intramedullary Kirschner wires were inserted into each specimen, using three different assembly patterns: Group I: locking with external minifixator at a height of 3.0 cm; Group II: locking at a height of 4.5 cm; Group III: without external locking. Mechanical shear tests were then conducted, to determine the maximum load, proportionality limit and coefficient of rigidity. Results: There were no significant differences in maximum load or proportionality limit between the groups. The coefficient of rigidity was higher in Group II. Conclusion: The locking height for the Kirschner wires in Ulson's method, within the limits evaluated, did not harm the stability of the fracture fixation system. |
References: | J Hand Surg Br. 2001 Dec;26(6):550-5. (PMID: 11884111) J Hand Surg Br. 2005 Aug;30(4):428-31. (PMID: 15935530) |
فهرسة مساهمة: | Keywords: Biomechanics; External Fixators; Radius Fractures |
تواريخ الأحداث: | Date Created: 20160331 Date Completed: 20160330 Latest Revision: 20200930 |
رمز التحديث: | 20240829 |
مُعرف محوري في PubMed: | PMC4799331 |
DOI: | 10.1016/S2255-4971(15)30321-9 |
PMID: | 27027069 |
قاعدة البيانات: | MEDLINE |
تدمد: | 2255-4971 |
---|---|
DOI: | 10.1016/S2255-4971(15)30321-9 |