دورية أكاديمية

Evaluation of Visunex Medical's PanoCam(TM) LT and PanoCam(TM) Pro wide-field imaging systems for the screening of ROP in newborn infants.

التفاصيل البيبلوغرافية
العنوان: Evaluation of Visunex Medical's PanoCam(TM) LT and PanoCam(TM) Pro wide-field imaging systems for the screening of ROP in newborn infants.
المؤلفون: Wood EH; a Byers Eye Institute, Department of Ophthalmology , Stanford University School of Medicine , Palo Alto , CA , USA., Moshfeghi AA; b USC Eye Institute, Department of Ophthalmology , University of Southern California Keck School of Medicine , Los Angeles , CA , USA., Nudleman ED; c Shiley Eye Institute, Department of Ophthalmology , University of California San Diego School of Medicine , La Jolla , CA , USA., Moshfeghi DM; a Byers Eye Institute, Department of Ophthalmology , Stanford University School of Medicine , Palo Alto , CA , USA.
المصدر: Expert review of medical devices [Expert Rev Med Devices] 2016 Aug; Vol. 13 (8), pp. 705-12.
نوع المنشور: Journal Article; Review
اللغة: English
بيانات الدورية: Publisher: Taylor & Francis Country of Publication: England NLM ID: 101230445 Publication Model: Print Cited Medium: Internet ISSN: 1745-2422 (Electronic) Linking ISSN: 17434440 NLM ISO Abbreviation: Expert Rev Med Devices Subsets: MEDLINE
أسماء مطبوعة: Publication: 2015- : Abingdon, Oxford : Taylor & Francis
Original Publication: London : Future Drugs Ltd.
مواضيع طبية MeSH: Diagnostic Imaging/*methods , Neonatal Screening/*methods , Retinopathy of Prematurity/*diagnosis, Fundus Oculi ; Humans ; Infant, Newborn ; Practice Guidelines as Topic ; Telemedicine
مستخلص: Introduction: Retinopathy of Prematurity (ROP) is a leading cause of childhood blindness. The incidence of ROP is rising, placing greater demands on the healthcare providers that serve these patients and their families. Telemedicine remote digital fundus imaging (TM-RDFI) plays a pivotal role in ROP management, and has allowed for the expansion of ROP care into previously underserved areas.
Areas Covered: A broad literature review through the pubmed index was undertaken with the goal of summarizing the current state of ROP and guidelines for its screening . Furthermore, all currently used telemedicine remote digital fundus imaging devices were analyzed both via the literature and the companies' websites/brochures. Finally, the PanoCam LT™ and PanoCam™ Pro created by Visunex Medical were analyzed via the company website/brochures. Expert commentary: The PanoCam LT™ and PanoCam™ Pro have recently been approved for use within the USA and CE marked for international commercialization in European Union and other countries requiring CE mark. These wide-field imaging systems have the intended use of ophthalmic imaging of all newborn babies and meet the requirements for ROP screening, thereby serving as competition within the ROP screening market previously dominated by one camera imaging system.
فهرسة مساهمة: Keywords: Telemedicine; newborn eye screening; ophthalmic imaging; remote digital fundus imaging; retinopathy of prematurity; universal screening; wide-field fundus photography
تواريخ الأحداث: Date Created: 20160719 Date Completed: 20170227 Latest Revision: 20170227
رمز التحديث: 20231215
DOI: 10.1080/17434440.2016.1208560
PMID: 27424884
قاعدة البيانات: MEDLINE
الوصف
تدمد:1745-2422
DOI:10.1080/17434440.2016.1208560