Evaluation of Blood Glucose Monitoring System in Screening for Neonatal Hypoglycemia: Tighter Accuracy Standard.

التفاصيل البيبلوغرافية
العنوان: Evaluation of Blood Glucose Monitoring System in Screening for Neonatal Hypoglycemia: Tighter Accuracy Standard.
المؤلفون: Tsao MF; 1 Department of Laboratory Medicine, Taipei Medical University Hospital, Taipei, Taiwan.; 2 School of Medical Laboratory Science and Biotechnology, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan., Chang HW; 1 Department of Laboratory Medicine, Taipei Medical University Hospital, Taipei, Taiwan.; 2 School of Medical Laboratory Science and Biotechnology, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan., Chang CH; 1 Department of Laboratory Medicine, Taipei Medical University Hospital, Taipei, Taiwan.; 2 School of Medical Laboratory Science and Biotechnology, College of Medical Science and Technology, Taipei Medical University, Taipei, Taiwan., Cheng CH; 1 Department of Laboratory Medicine, Taipei Medical University Hospital, Taipei, Taiwan., Lin HC; 1 Department of Laboratory Medicine, Taipei Medical University Hospital, Taipei, Taiwan.; 3 Department of Pediatrics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
المصدر: Journal of diabetes science and technology [J Diabetes Sci Technol] 2017 May; Vol. 11 (3), pp. 639-640. Date of Electronic Publication: 2016 Sep 14.
نوع المنشور: Clinical Trial; Multicenter Study; Letter
اللغة: English
بيانات الدورية: Publisher: Sage Country of Publication: United States NLM ID: 101306166 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1932-2968 (Electronic) Linking ISSN: 19322968 NLM ISO Abbreviation: J Diabetes Sci Technol Subsets: MEDLINE
أسماء مطبوعة: Publication: 2014- : Thousand Oaks, CA : Sage
Original Publication: Foster City, CA : Diabetes Technology Society
مواضيع طبية MeSH: Blood Glucose/*analysis , Hypoglycemia/*blood , Hypoglycemia/*diagnosis , Neonatal Screening/*instrumentation, Humans ; Infant, Newborn
مستخلص: Neonatal hypoglycemia may cause severe neurological damages; therefore, tight glycemic control is crucial to identify neonate at risk. Previous blood glucose monitoring system (BGMS) failed to perform well in neonates; there are calls for the tightening of accuracy requirements. It remains a need for accurate BGMS for effective bedside diabetes management in neonatal care within a hospital population. A total of 300 neonates were recruited from local hospitals. Accuracy performance of a commercially available BGMS was evaluated against reference instrument in screening for neonatal hypoglycemia, and assessment was made based on the ISO15197:2013 and a tighter standard. At blood glucose level < 47 mg/dl, BGMS assessed met the minimal accuracy requirement of ISO 15197:2013 and tighter standard at 100% and 97.2%, respectively.
References: Pediatrics. 2011 Mar;127(3):575-9. (PMID: 21357346)
Pediatrics. 2000 May;105(5):1141-5. (PMID: 10790476)
J Pediatr. 2012 Nov;161(5):787-91. (PMID: 22727868)
Biol Neonate. 2006;90(2):74-86. (PMID: 16534190)
Eur J Pediatr. 2013 Sep;172(9):1181-6. (PMID: 23644649)
Curr Opin Endocrinol Diabetes Obes. 2014 Feb;21(1):45-50. (PMID: 24275620)
فهرسة مساهمة: Keywords: accuracy; blood glucose monitoring system; hematocrit; hypoglycemia; neonate
المشرفين على المادة: 0 (Blood Glucose)
تواريخ الأحداث: Date Created: 20160917 Date Completed: 20180426 Latest Revision: 20181113
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC5505412
DOI: 10.1177/1932296816668878
PMID: 27633318
قاعدة البيانات: MEDLINE
الوصف
تدمد:1932-2968
DOI:10.1177/1932296816668878