دورية أكاديمية

Comparison of paper spray mass spectrometry analysis of dried blood spots from devices used for in-field collection of clinical samples.

التفاصيل البيبلوغرافية
العنوان: Comparison of paper spray mass spectrometry analysis of dried blood spots from devices used for in-field collection of clinical samples.
المؤلفون: Yannell KE; Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA., Kesely KR; Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA., Chien HD; Huế University of Medicine and Pharmacy, Huế, Vietnam., Kissinger CB; Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA., Cooks RG; Department of Chemistry, Purdue University, West Lafayette, IN, 47907, USA. cooks@purdue.edu.
المصدر: Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2017 Jan; Vol. 409 (1), pp. 121-131. Date of Electronic Publication: 2016 Nov 07.
نوع المنشور: Comparative Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: Springer-Verlag Country of Publication: Germany NLM ID: 101134327 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1618-2650 (Electronic) Linking ISSN: 16182642 NLM ISO Abbreviation: Anal Bioanal Chem Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Heidelberg : Springer-Verlag, 2002-
مواضيع طبية MeSH: Antineoplastic Agents/*blood , Benzamides/*blood , Dried Blood Spot Testing/*methods , Drug Monitoring/*methods , Imatinib Mesylate/*blood , Piperazines/*blood , Tandem Mass Spectrometry/*methods, Blood Specimen Collection/instrumentation ; Blood Specimen Collection/methods ; Dried Blood Spot Testing/instrumentation ; Drug Monitoring/instrumentation ; Equipment Design ; Humans ; Limit of Detection ; Paper ; Tandem Mass Spectrometry/instrumentation
مستخلص: Paper spray (PS) is an ambient ionization technique applicable to ionizing analytes from untreated dried biofluid samples. In-field sample analysis could benefit from the capability to use a finger prick of blood to measure drugs in whole blood at low cost and in a short time. Some studies may require specialized blood collection devices that can be used in remote areas. In this study, four different dried blood spot (DBS) devices are used with PS sources and tested for rapid quantification of imatinib and N-desmethyl-imatinib. A triple quadrupole mass spectrometer allows analyte detection with high sensitivity. Analytical figures of merit for the four devices are compared, and it is concluded that several of the novel devices successfully deploy DBS with PS and yield similar results to traditional manual PS methods. Clinical samples collected in a remote location were analyzed as a proof of concept for in-field blood collection and subsequent rapid laboratory analysis. Graphical abstract Dried blood spot analyis by paper spray ionization MS/MS for in field sample collection.
فهرسة مساهمة: Keywords: Field sample collection; Imatinib; Multiple reaction monitoring; Paper spray ionization; Therapeutic drug monitoring
المشرفين على المادة: 0 (Antineoplastic Agents)
0 (Benzamides)
0 (Piperazines)
6GOH0N63QD (N-desmethylimatinib)
8A1O1M485B (Imatinib Mesylate)
تواريخ الأحداث: Date Created: 20161109 Date Completed: 20180221 Latest Revision: 20190117
رمز التحديث: 20240628
DOI: 10.1007/s00216-016-9954-5
PMID: 27822645
قاعدة البيانات: MEDLINE
الوصف
تدمد:1618-2650
DOI:10.1007/s00216-016-9954-5