دورية أكاديمية

Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

التفاصيل البيبلوغرافية
العنوان: Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!
المؤلفون: Thabouillot O; 1Emergency Department,Begin Military Hospital,Saint-Mandé,France., Bostanci K; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France., Bouvier F; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France., Dumitrescu N; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France., Stéfuriac M; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France., Paule P; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France., Roche NC; 2Department of Cardiology,Begin Military Hospital,Saint-Mandé,France.
المصدر: Prehospital and disaster medicine [Prehosp Disaster Med] 2017 Dec; Vol. 32 (6), pp. 691-693. Date of Electronic Publication: 2017 Aug 15.
نوع المنشور: Case Reports; Journal Article
اللغة: English
بيانات الدورية: Publisher: Cambridge University Press Country of Publication: United States NLM ID: 8918173 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1945-1938 (Electronic) Linking ISSN: 1049023X NLM ISO Abbreviation: Prehosp Disaster Med
أسماء مطبوعة: Publication: 2011- : New York : Cambridge University Press
Original Publication: [Solana Beach, CA] : Jems Pub. Co., [c1989]-
مواضيع طبية MeSH: Running*, Atrial Fibrillation/*diagnosis , Syncope/*diagnosis, Atrial Fibrillation/etiology ; Atrial Fibrillation/prevention & control ; Diagnosis, Differential ; Electrocardiography, Ambulatory ; Heart Rate ; Humans ; Male ; Middle Aged ; Syncope/etiology ; Syncope/prevention & control
مستخلص: This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.
فهرسة مساهمة: Keywords: AF atrial fibrillation; ECG electrocardiogram; HRM heart rate monitor; atrial fibrillation; sport; syncope
تواريخ الأحداث: Date Created: 20170816 Date Completed: 20180726 Latest Revision: 20180726
رمز التحديث: 20231215