دورية أكاديمية
Analysis of temperature increase in swine gingiva after exposure to a Polywave ® LED light curing unit.
العنوان: | Analysis of temperature increase in swine gingiva after exposure to a Polywave ® LED light curing unit. |
---|---|
المؤلفون: | Maucoski C; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil., Zarpellon DC; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil., Dos Santos FA; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil., Lipinski LC; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil., Campagnoli EB; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil., Rueggeberg FA; Dental Materials Section, Department of Restorative Sciences, Dental College of Georgia, Room GC 4344, Augusta University, 1430 John Wesley Gilbert Drive, Augusta, GA 30912, USA. Electronic address: frueggeb@augusta.edu., Arrais CAG; Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa, 84030-900 Parana, Brazil. |
المصدر: | Dental materials : official publication of the Academy of Dental Materials [Dent Mater] 2017 Nov; Vol. 33 (11), pp. 1266-1273. Date of Electronic Publication: 2017 Aug 18. |
نوع المنشور: | Journal Article; Research Support, Non-U.S. Gov't |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Science Country of Publication: England NLM ID: 8508040 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1879-0097 (Electronic) Linking ISSN: 01095641 NLM ISO Abbreviation: Dent Mater |
أسماء مطبوعة: | Publication: 1998- : Kidlington, Oxford, UK : Elsevier Science Original Publication: Copenhagen : Munksgaard, c1985- |
مواضيع طبية MeSH: | Curing Lights, Dental* , Temperature*, Gingiva/*radiation effects, Animals ; Radiation Injuries/prevention & control ; Swine |
مستخلص: | Objective: This study evaluated the temperature increase in swine gingival temperature after exposure to light emitted by a Polywave ® LED light curing unit (LCU, Bluephase 20i, Ivoclar Vivadent). Methods: After local Ethics Committee approval (protocol 711/2015), 40 pigs were subjected to general anesthesia and the LCU tip was placed 5mm from the buccal gingival tissue (GT) close to lower lateral incisors. A thermocouple probe (Thermes WFI, Physitemp) was inserted into the gingival sulcus before and immediately after exposure to light. Real-time temperature (°C) was measured after the following exposure modes were applied: High Power (20s-H, 40s-H, and 60s-H) or Turbo mode (5s-T), either with or without the presence of rubber dam (RD) interposed between the LCU tip and GT (n=10). The presence of gingival lesions after the exposures was also evaluated. Peak temperature (°C) and the temperature increase during exposure over that of the pre-exposure baseline value (ΔT) data were analyzed using 2-way ANOVA followed by Bonferroni's post-hoc test (α=5%). A binary logistic regression analysis determined the risk of gingival lesion development. Results: Without RD, no significant difference in ΔT was observed among 20s-H, 40s-H, and 60s-H groups, which showed the highest temperature values, while the 5s-T exposure showed the lowest ΔT, regardless of RD. RD reduced ΔT only for the 20s-H group (p=0.004). Gingival lesions were predominantly observed using 40s-H, with RD, and 60s-H, with and without RD. Significance: Exposure to a LCU light might be harmful to swine gingiva only when high radiant exposure values are delivered, regardless of the use of RD. (Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.) |
فهرسة مساهمة: | Keywords: Dental curing lights; Gingiva; Temperature |
تواريخ الأحداث: | Date Created: 20170823 Date Completed: 20180709 Latest Revision: 20180723 |
رمز التحديث: | 20221213 |
DOI: | 10.1016/j.dental.2017.07.021 |
PMID: | 28826611 |
قاعدة البيانات: | MEDLINE |
تدمد: | 1879-0097 |
---|---|
DOI: | 10.1016/j.dental.2017.07.021 |