دورية أكاديمية

A novel entry point for pedicle screw placement in the thoracic spine.

التفاصيل البيبلوغرافية
العنوان: A novel entry point for pedicle screw placement in the thoracic spine.
المؤلفون: Sun ZF; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Yang KX; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Chen HT; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Sui T; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Yang L; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Ge DW; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Tang J; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China., Cao XJ; Department of Orthopaedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, China.
المصدر: Journal of biomedical research [J Biomed Res] 2018 Mar 26; Vol. 32 (2), pp. 123-129.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Editorial Department of the Journals of Nanjing Medical University Country of Publication: China NLM ID: 101551157 Publication Model: Print Cited Medium: Print ISSN: 1674-8301 (Print) Linking ISSN: 16748301 NLM ISO Abbreviation: J Biomed Res Subsets: PubMed not MEDLINE
أسماء مطبوعة: Publication: [Nanjing] : Editorial Department of the Journals of Nanjing Medical University
Original Publication: Nanjing : Education Dept. of Jiangsu Province
مستخلص: This study was aimed to introduce a novel entry point for pedicle screw fixation in the thoracic spine and compare it with the traditional entry point. A novel entry point was found with the aim of improving accuracy, safety and stability of pedicle screw technique based on anatomical structures of the spine. A total of 76 pieces of normal thoracic CT images at the transverse plane and the thoracic pedicle anatomy of 6 cadaveric specimens were recruited. Transverse pedicle angle (TPA), screw length, screw placement accuracy rate and axial pullout strength of the two different entry point groups were compared. There were significant differences in the TPA, screw length, and the screw placement accuracy rate between the two groups ( P <0.05). The maximum axial pullout strength of the novel entry point group was slightly larger than that of the traditional group. However, the difference was not significant ( P >0.05). The novel entry point significantly improved the accuracy, stability and safety of pedicle screw placement. With reference to the advantages above, the new entry point can be used for spinal internal fixations in the thoracic spine.
References: Spine (Phila Pa 1976). 2005 Jan 15;30(2):222-6. (PMID: 15644761)
Neurosurgery. 2001 Apr;48(4):771-8; discussion 778-9. (PMID: 11322437)
J Neurosurg Spine. 2012 Aug;17(2):113-22. (PMID: 22724594)
Spine (Phila Pa 1976). 1992 Mar;17(3):299-306. (PMID: 1566168)
Spine (Phila Pa 1976). 2000 Mar 1;25(5):606-14. (PMID: 10749638)
Spine (Phila Pa 1976). 2008 May 1;33(10 ):1141-8. (PMID: 18449050)
Eur Spine J. 1994;3(4):184-201. (PMID: 7866834)
Orthop Traumatol Surg Res. 2014 Sep;100(5):475-80. (PMID: 25106100)
Clin Orthop Relat Res. 1992 Nov;(284):34-46. (PMID: 1395312)
Spine (Phila Pa 1976). 2003 Sep 15;28(18):2058-65. (PMID: 14501914)
J Neurosurg Spine. 2013 Feb;18(2):178-83. (PMID: 23198696)
Orthop Clin North Am. 1986 Jan;17 (1):147-59. (PMID: 3945476)
Spine (Phila Pa 1976). 1997 Jun 1;22(11):1254-8. (PMID: 9201865)
Spine (Phila Pa 1976). 1999 Jan 1;24(1):18-24, discussion 25. (PMID: 9921586)
Eur Spine J. 2000 Jun;9(3):235-40. (PMID: 10905443)
Spine (Phila Pa 1976). 2001 Nov 1;26(21):2340-6. (PMID: 11679819)
SAS J. 2011 Sep 01;5(3):57-62. (PMID: 25802669)
Zhonghua Wai Ke Za Zhi. 2005 Oct 15;43(20):1328-30. (PMID: 16271246)
J Spinal Disord Tech. 2008 Feb;21(1):63-7. (PMID: 18418139)
J Bone Joint Surg Am. 2000 Oct;82-A(10):1458-76. (PMID: 11057475)
J Spinal Disord. 1998 Jun;11(3):215-20. (PMID: 9657546)
Neurosurgery. 2002 Nov;51(5 Suppl):S166-81. (PMID: 12234445)
J Pediatr Orthop. 2007 Jul-Aug;27(5):582-6. (PMID: 17585271)
Spine (Phila Pa 1976). 2004 Feb 1;29(3):333-42; discussion 342. (PMID: 14752359)
J Korean Neurosurg Soc. 2012 Jan;51(1):66-70. (PMID: 22396849)
Spine (Phila Pa 1976). 2003 Jan 1;28(1):91-7. (PMID: 12544964)
Eur Spine J. 2007 Jul;16(7):1047-54. (PMID: 17273838)
Spine (Phila Pa 1976). 1999 Jan 15;24(2):114-9. (PMID: 9926379)
تواريخ الأحداث: Date Created: 20170904 Latest Revision: 20200929
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC5895566
DOI: 10.7555/JBR.31.20160037
PMID: 28866657
قاعدة البيانات: MEDLINE
الوصف
تدمد:1674-8301
DOI:10.7555/JBR.31.20160037