دورية أكاديمية

Reference values and reliability for lumbopelvic strength and endurance in asymptomatic subjects.

التفاصيل البيبلوغرافية
العنوان: Reference values and reliability for lumbopelvic strength and endurance in asymptomatic subjects.
المؤلفون: Oliveira IO; Universidade de São Paulo (USP), Faculdade de Medicina de Ribeirão Preto (FMRP), Programa de Pós-graduação em Reabilitação e Desempenho Funcional, Ribeirão Preto, SP, Brazil; Instituto Wilson Mello, Núcleo de Estudos e Pesquisa, Campinas, SP, Brazil. Electronic address: isadoraooliveira@gmail.com., Pilz B; Universidade de São Paulo (USP), Faculdade de Medicina de Ribeirão Preto (FMRP), Programa de Pós-graduação em Reabilitação e Desempenho Funcional, Ribeirão Preto, SP, Brazil; Instituto Wilson Mello, Núcleo de Estudos e Pesquisa, Campinas, SP, Brazil., Santos RLG Junior; Universidade de São Paulo (USP), Faculdade de Medicina de Ribeirão Preto (FMRP), Programa de Pós-graduação em Reabilitação e Desempenho Funcional, Ribeirão Preto, SP, Brazil., Vasconcelos RA; Universidade de São Paulo (USP), Faculdade de Medicina de Ribeirão Preto (FMRP), Programa de Pós-graduação em Reabilitação e Desempenho Funcional, Ribeirão Preto, SP, Brazil; Instituto Wilson Mello, Núcleo de Estudos e Pesquisa, Campinas, SP, Brazil., Mello W; Instituto Wilson Mello, Núcleo de Estudos e Pesquisa, Campinas, SP, Brazil., Grossi DB; Universidade de São Paulo (USP), Faculdade de Medicina de Ribeirão Preto (FMRP), Programa de Pós-graduação em Reabilitação e Desempenho Funcional, Ribeirão Preto, SP, Brazil.
المصدر: Brazilian journal of physical therapy [Braz J Phys Ther] 2018 Jan - Feb; Vol. 22 (1), pp. 33-41. Date of Electronic Publication: 2017 Sep 29.
نوع المنشور: Journal Article; Observational Study
اللغة: English
بيانات الدورية: Publisher: Elsevier B.V Country of Publication: Brazil NLM ID: 101615124 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1809-9246 (Electronic) Linking ISSN: 14133555 NLM ISO Abbreviation: Braz J Phys Ther Subsets: MEDLINE
أسماء مطبوعة: Publication: 2017-: Amsterdam, The Netherlands : Elsevier B.V.
Original Publication: São Carlos, SP - Brasil : Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterpia, 2013.
مواضيع طبية MeSH: Abdominal Muscles/*physiology , Muscle Contraction/*physiology , Muscle Strength/*physiology , Muscle, Skeletal/*physiology, Hip ; Humans ; Isometric Contraction/physiology ; Lumbosacral Region ; Pelvis ; Physical Endurance ; Reference Values ; Reproducibility of Results
مستخلص: Background: Assessing the lumbopelvic region is useful for detecting many musculoskeletal dysfunctions and also performance deficits. Several clinical tests are used to assess this region, however, reference values and results related to method, reliability and error measurements of these tests have not been reported.
Objectives: To establish reference values and determine reliability, standard error of measurement (SEM), typical error of measurement (TEM) and minimum detectable change (MDC) of a set of clinical tests used for assessing the lumbopelvic region in subjects divided by gender, age group and physical activity levels.
Methods: An observational study was conducted. For reference values, 152 subjects performed eight clinical tests (isometric strength of hip muscles; deep abdominal function and endurance tests) used to assess the lumbopelvic region. Reliability analyses were assessed using the Intraclass Correlation Coefficient (ICC 2,1 ) and error measurements were calculated by using the SEM, TEM and the MDC.
Results: Reference values were established for each group and results showed significant (p<0.05) differences concerning gender, age group and physical activity levels in clinical tests. All tests presented good reliability indices with an ICC higher than 0.80 for reliability; MDC values were greater than mean of SEM in all tests, confirming its usage for clinical practice assessments.
Conclusion: Reference values are necessary in the evaluation of subjects and these results can contribute for clinical practice, providing clinical training targets. Also, evaluation of reliability and error measurements in this set of tests allows its use in clinical practice.
(Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.)
References: Disabil Rehabil. 2016 Sep;38(19):1859-71. (PMID: 26732899)
Int J Sports Phys Ther. 2014 Oct;9(5):604-16. (PMID: 25328823)
J Orthop Sports Phys Ther. 2008 Aug;38(8):485-501. (PMID: 18678961)
J Manipulative Physiol Ther. 2013 Jan;36(1):33-43. (PMID: 23380212)
J Manipulative Physiol Ther. 2012 May;35(4):279-85. (PMID: 22632587)
Phys Ther. 1986 Feb;66(2):206-9. (PMID: 3945674)
Clin Biomech (Bristol, Avon). 2003 Aug;18(7):662-9. (PMID: 12880714)
Physiother Res Int. 1996;1(1):30-40. (PMID: 9238721)
Clin Orthop Relat Res. 2014 Feb;472(2):654-64. (PMID: 23817756)
J Orthop Sports Phys Ther. 2010 Oct;40(10):641-7. (PMID: 20508327)
J Strength Cond Res. 2005 Feb;19(1):231-40. (PMID: 15705040)
Rev Bras Fisioter. 2012 Sep-Oct;16(5):389-95. (PMID: 22832703)
Clin Biomech (Bristol, Avon). 2001 Jan;16(1):38-46. (PMID: 11114442)
Am J Phys Med Rehabil. 2007 May;86(5):380-386. (PMID: 17303961)
PM R. 2011 May;3(5):472-9. (PMID: 21570036)
Sports Med. 2000 Jul;30(1):1-15. (PMID: 10907753)
J Sport Rehabil. 2008 May;17(2):160-70. (PMID: 18515915)
J Med Assoc Thai. 2015 Jun;98 Suppl 5:S23-8. (PMID: 26387407)
Arch Phys Med Rehabil. 1997 Jan;78(1):26-32. (PMID: 9014953)
Phys Ther. 1996 Mar;76(3):248-59. (PMID: 8602410)
Braz J Phys Ther. 2016 Jan 19;20(2):105-13. (PMID: 26786084)
Stat Med. 1998 Jan 15;17(1):101-10. (PMID: 9463853)
Spine (Phila Pa 1976). 2001 Apr 1;26(7):771-7. (PMID: 11295899)
Arch Phys Med Rehabil. 2004 Apr;85(4):598-603. (PMID: 15083436)
Phys Ther. 2016 Jul;96(7):1057-66. (PMID: 26637653)
J Sci Med Sport. 2007 Dec;10(6):447-55. (PMID: 17141568)
Br J Sports Med. 2005 Oct;39(10):731-5. (PMID: 16183769)
Exp Biol Med (Maywood). 2003 Jun;228(6):706-9. (PMID: 12773702)
Clin Biomech (Bristol, Avon). 1995 Sep;10(6):323-324. (PMID: 11415574)
J Bodyw Mov Ther. 2010 Jan;14(1):84-98. (PMID: 20006294)
J Orthop Sports Phys Ther. 2005 Dec;35(12):793-801. (PMID: 16848100)
Arch Phys Med Rehabil. 1999 Aug;80(8):941-4. (PMID: 10453772)
Spine (Phila Pa 1976). 1999 Oct 15;24(20):2085-9; discussion 2090. (PMID: 10543003)
J Manipulative Physiol Ther. 2016 Jun;39(5):359-368. (PMID: 27167368)
Amyotroph Lateral Scler. 2007 Feb;8(1):47-55. (PMID: 17364436)
Spine (Phila Pa 1976). 2004 Dec 1;29(23):2593-602. (PMID: 15564907)
Physiotherapy. 2011 Jun;97(2):100-6. (PMID: 21497243)
J Orthop Sports Phys Ther. 2006 Mar;36(3):138-51. (PMID: 16596890)
J Neuroeng Rehabil. 2013 Jun 18;10:60. (PMID: 23777436)
فهرسة مساهمة: Keywords: Hand held dynamometer; Hip; Physical endurance; Physical therapy; Spine
تواريخ الأحداث: Date Created: 20171017 Date Completed: 20180308 Latest Revision: 20240315
رمز التحديث: 20240315
مُعرف محوري في PubMed: PMC5816085
DOI: 10.1016/j.bjpt.2017.09.008
PMID: 29031958
قاعدة البيانات: MEDLINE
الوصف
تدمد:1809-9246
DOI:10.1016/j.bjpt.2017.09.008