Planning a total knee arthroplasty through an application for mobile devices: case report.
العنوان: | Planning a total knee arthroplasty through an application for mobile devices: case report. |
---|---|
المؤلفون: | Nogueira JBS; Departamento de Pós-graduação, Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, CE, Brazil., Carvalho ACGS; Centro Universitário Christus, Fortaleza, CE, Brazil., Barros Filho EM; Centro Universitário Christus, Fortaleza, CE, Brazil., Araújo LHDC; Departamento de Ortopedia e Traumatologia, Santa Casa da Misericórdia de Fortaleza, Fortaleza, CE, Brazil., Bezerra MJC; Faculdade de Medicina, Universidade de Fortaleza (Unifor), Fortaleza, CE, Brazil., Leite JAD; Departamento de Pós-graduação, Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, CE, Brazil. |
المصدر: | Revista brasileira de ortopedia [Rev Bras Ortop] 2018 Sep 19; Vol. 53 (6), pp. 792-796. Date of Electronic Publication: 2018 Sep 19 (Print Publication: 2018). |
نوع المنشور: | Case Reports |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Ltda Country of Publication: Brazil NLM ID: 101660959 Publication Model: eCollection Cited Medium: Print ISSN: 2255-4971 (Print) Linking ISSN: 22554971 NLM ISO Abbreviation: Rev Bras Ortop Subsets: PubMed not MEDLINE |
أسماء مطبوعة: | Original Publication: Rio de Janeiro : Elsevier Ltda, [2009]-[2018] |
مستخلص: | For decades, the main cause of failure in total knee arthroplasty (TKA) is still the malalignment of prosthetic components. The authors present a case of advanced knee arthrosis, treated by TKA. Preoperative planning was performed with a mobile application and the patient was submitted to primary TKA using an implant developed with inspiration from the theory of "modified GAP" with a rotated tibial tray. Neutral mechanical alignment of the lower limbs was obtained and the application proved to be viable regarding its proposed plan for this case. |
References: | Indian J Orthop. 2013 Jan;47(1):35-9. (PMID: 23532339) J Arthroplasty. 2014 Jun;29(6):1133-7. (PMID: 24355255) Knee. 2013 Aug;20(4):242-9. (PMID: 22892197) Bone Joint J. 2014 Jul;96-B(7):907-13. (PMID: 24986944) J Bone Joint Surg Br. 1991 Sep;73(5):709-14. (PMID: 1894655) Open Orthop J. 2016 Jul 28;10:357-63. (PMID: 27563365) Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2271-80. (PMID: 23948721) Int Orthop. 2013 Jan;37(1):45-50. (PMID: 23232654) Open Orthop J. 2015 Sep 30;9:489-94. (PMID: 26587067) Surgery. 2015 Nov;158(5):1352-71. (PMID: 25964029) Rev Bras Ortop. 2018 Feb 27;53(2):142-150. (PMID: 29911079) Wien Klin Wochenschr. 2015 Dec;127 Suppl 5:S235-40. (PMID: 25732915) |
فهرسة مساهمة: | Keywords: Arthroplasty replacement knee; Bone malalignment; Mobile applications Local Abstract: [Publisher, Portuguese] Ao longo das décadas, a principal causa de insucesso em artroplastias totais do joelho (ATJ) continua a ser o mau alinhamento dos componentes protéticos. Os autores apresentam um caso de artrose avançada do joelho tratado por ATJ. O planejamento pré-operatório foi feito a partir de um aplicativo para dispositivos móveis e a paciente foi submetida à ATJ primária, com um implante desenvolvido com inspiração na teoria do “GAP modificado”, com base tibial rotatória. O alinhamento mecânico neutro dos membros inferiores foi obtido e o aplicativo mostrou-se viável em sua proposta de planejamento para este caso. |
تواريخ الأحداث: | Date Created: 20181101 Latest Revision: 20201001 |
رمز التحديث: | 20240829 |
مُعرف محوري في PubMed: | PMC6204531 |
DOI: | 10.1016/j.rboe.2018.09.001 |
PMID: | 30377618 |
قاعدة البيانات: | MEDLINE |
تدمد: | 2255-4971 |
---|---|