دورية أكاديمية

Impact of Distinct Freezing Curves on the Quality of Ram Sperm after Thawing.

التفاصيل البيبلوغرافية
العنوان: Impact of Distinct Freezing Curves on the Quality of Ram Sperm after Thawing.
المؤلفون: Ferreira CER; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., Goularte KL; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., da Cruz Tavares G; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., Gheller SMM; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., Mondadori RG; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Instituto de Biologia,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., Vieira AD; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil., Lucia T Jr; ReproPel, Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil; Faculdade de Veterinária,Universidade Federal de Pelotas, 96010-900, Pelotas-RS, Brazil. thomaz@ufpel.edu.br, thomaz@pq.cnpq.br.
المصدر: Cryo letters [Cryo Letters] 2019 May/Jun; Vol. 40 (3), pp. 193-199.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: CryoLetters Country of Publication: England NLM ID: 9891832 Publication Model: Print Cited Medium: Print ISSN: 0143-2044 (Print) Linking ISSN: 01432044 NLM ISO Abbreviation: Cryo Letters
أسماء مطبوعة: Publication: London, Eng. : CryoLetters
Original Publication: [London : Royal Veterinary College,
مواضيع طبية MeSH: Sperm Motility*, Cryopreservation/*veterinary , Semen Preservation/*veterinary , Spermatozoa/*physiology, Animals ; Freezing ; Male ; Sheep
مستخلص: Background: Automated equipment with customized freezing curves can be used to cryopreserve ram sperm, but none is considered a standard.
Objective: This study compared the post-thawing quality of ram sperm frozen using a conventional freezing curve and two controlled-rate curves.
Materials and Methods: Six ejaculates were collected from four rams (n = 24). In the conventional curve (110 min), sperm was cooled at -0.3 to -0.5°C min -1 until 5°C, stabilized for 60 min and exposed to liquid nitrogen (LN 2 ) vapor for 10 min (-80°C) before submersion. The slow-customized (SC) curve (126.2 min) used a rate of -0.25°C min -1 until 5°C, stabilization for 60 min and a rate of -20°C min -1 until -120°C before immersion in LN 2 . Rates for the fast-customized (FC) curve (75 min) were: -0.3°C min -1 until 5°C; -3°C min -1 until -10°C; -5°C min -1 until -35°C; and -4°C min -1 until immersion in LN 2 (-43°C).
Results: Velocity in a straight line and beat-cross frequency were lower for spermatozoa frozen with the FC than with the conventional curve (P < 0.05). The FC curve resulted in more membrane and acrosome damages than the other curves (P < 0.05). Mitochondrial membrane potential was lower with the SC than with the other curves (P < 0.05).
Conclusion: The conventional curve was more efficient than both tested automated freezing curves. The FC curve may be an alternative to the SC curve due to the shorter processing time.