Validity of clinical methods in the detection of leg-length discrepancies.

التفاصيل البيبلوغرافية
العنوان: Validity of clinical methods in the detection of leg-length discrepancies.
المؤلفون: Gomez-Aguilar E; Podiatry Department, University of Seville, Spain., Reina-Bueno M; Podiatry Department, University of Seville, Spain., Lafuente-Sotillos G; Podiatry Department, University of Seville, Spain., Montes-Salas R; Vitruvius Institute of Biomechanics and Health, Madrid, Spain., Munuera-Martinez PV; Podiatry Department, University of Seville, Spain., Castillo-Lopez JM; Podiatry Department, University of Seville, Spain.
المصدر: Hip international : the journal of clinical and experimental research on hip pathology and therapy [Hip Int] 2021 Mar; Vol. 31 (2), pp. 186-190. Date of Electronic Publication: 2020 Mar 03.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: SAGE Publishing Country of Publication: United States NLM ID: 9200413 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1724-6067 (Electronic) Linking ISSN: 11207000 NLM ISO Abbreviation: Hip Int Subsets: MEDLINE
أسماء مطبوعة: Publication: 2018- : Thousand Oaks, CA : SAGE Publishing
Original Publication: Milano, Italy : Wichtig, c1991-
مواضيع طبية MeSH: Leg* , Leg Length Inequality*/diagnostic imaging, Femur ; Humans ; Lower Extremity ; Radiography
مستخلص: Introduction: Lower limb-length discrepancy is highly prevalent in the general population. Numerous methods and measurement instruments for its diagnosis appear in the literature, but there has not been an agreement about their validity. The aim of this work is to determine the validity of the Weber-Barstow manoeuvre (WB) of the pelvic measuring device (PMD) and the block method (BM), in comparison with standing anteroposterior telemetry of the lower limbs in subjects with leg-length discrepancy (LLD).
Methods: 71 subjects took part in the study. First, the WB was carried out in the supine position. the LLD was then quantified standing with the PMD and with the BM. Lastly, standing anteroposterior telemetry of the lower limbs was obtained. This was measured with Autocad 2013, using the highest part of the head of the femur and the most distal edge of the bisection of the femur as points of reference.
Results: The Kappa index was calculated to check the agreement between the WB manoeuvre and the telemetry. This was 0.52. The relation of the PMD, BM and telemetry difference variables was calculated. A direct relation between the BM and telemetry was shown, with p  > 0.05 (0.48 cm and 0.51 cm, respectively).
Conclusions: The WB manoeuvre got acceptable validity results. The PMD was not valid according to the results obtained in this work. The BM achieved a good validity result for the diagnosis of LLD.
فهرسة مساهمة: Keywords: Clinical measurements; lower limbs discrepancy; radiological tests; reliability
تواريخ الأحداث: Date Created: 20200305 Date Completed: 20210427 Latest Revision: 20220421
رمز التحديث: 20221213
DOI: 10.1177/1120700020910108
PMID: 32126845
قاعدة البيانات: MEDLINE