دورية أكاديمية

Effect of bleaching protocols on surface roughness and color change of high- and low-viscosity bulk-fill composite resins.

التفاصيل البيبلوغرافية
العنوان: Effect of bleaching protocols on surface roughness and color change of high- and low-viscosity bulk-fill composite resins.
عنوان ترانسليتريتد: Efeito de protocolos clareadores na rugosidade de superfície e alteração de cor de resinas compostas bulk-fill de alta e baixa viscosidade.
المؤلفون: Tavares BG; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, São Paulo, Brasil., França FM; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, São Paulo, Brasil., Basting RT; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, São Paulo, Brasil., Turssi CP; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, São Paulo, Brasil., Amaral FL; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, São Paulo, Brasil. flbamaral@gmail.com.
المصدر: Acta odontologica latinoamericana : AOL [Acta Odontol Latinoam] 2020 Sep 01; Vol. 33 (2), pp. 59-68.
نوع المنشور: Journal Article; Randomized Controlled Trial
اللغة: English
بيانات الدورية: Publisher: Acta Odontologica Latinoamericana Country of Publication: Argentina NLM ID: 8610218 Publication Model: Print Cited Medium: Internet ISSN: 1852-4834 (Electronic) Linking ISSN: 03264815 NLM ISO Abbreviation: Acta Odontol Latinoam
أسماء مطبوعة: Original Publication: Buenos Aires : Acta Odontologica Latinoamericana
مواضيع طبية MeSH: Composite Resins/*chemistry , Hydrogen Peroxide/*chemistry , Tooth Bleaching/*methods , Tooth Bleaching Agents/*chemistry , Tooth Discoloration/*drug therapy , Viscosity/*drug effects, Color ; Humans ; Materials Testing
مستخلص: The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.
Competing Interests: none
(Sociedad Argentina de Investigación Odontológica.)
References: Alzraikat H, Burrow MF, Maghaireh GA, Taha NA. Nanofilled resin compcosite properties and clinical performance: a review. Oper Dent 2018; 4: E173-E190.
Han SH, Park SH. Incremental and bulk-fill techniques with bulk-fill resin composite in different cavity configurations. Oper Dent 2018; 43: 631-641.
Park J, Chang J, Ferracane J, Lee IB. How should composite be layered to reduce shrinkage stress: incremental or bulk filling? Dent Mater 2008; 24: 1501-1505.
Soares CJ, Faria-E-Silva AL, Rodrigues MP, Vilela ABF, Pfeifer CS, Tantbirojn D, Versluis A. Polymerization shrinkage stress of composite resins and resin cements - what do we need to know? Braz Oral Res 2017; 31(suppl 1): e62.
Chandrasekhar V, Rudrapati L, Badami V, Tummala M. Incremental techniques in direct composite restoration. J Conserv Dent 2017; 20: 386-391.
Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig 2013; 17: 227-235.
Leprince JG, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G. Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent 2014; 42: 993-1000.
Tardem C, Albuquerque EG, Lopes LS, Marins SS, et al. Clinical time and postoperative sensitivity after use of bulkfill (syringe and capsule) vs. incremental filling composites: a randomized clinical trial. Braz Oral Res 2019; 33: e089.
Vianna-de-Pinho MG, Rego GF, Vidal ML, Alonso RCB, Schneider LFJ, Cavalcante LM. Clinical time required and internal adaptation in cavities restored with bulk-fill composites. J Contemp Dent Pract 2017; 18: 1107-1111.
Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR technology. Dent Mater 2011; 27: 348-355.
Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig 2014; 18: 1991-2000.
Van Ende A, De Munck J, Lise DP, Van Meerbeek B. Bulk- Fill composites: a review of the current literature. J Adhes Dent 2017; 19: 95-109.
Carey CM. Tooth whitening: what we now know. J Evid Based Dent Pract 2014; 14 Suppl: 70-76.
Jadad E, Montoya J, Arana G, Gordillo LA, Palo RM, Loguercio AD. Spectrophotometric evaluation of color alterations with a new dental bleaching product in patients wearing orthodontic appliances. Am J Orthod Dentofacial Orthop 2011; 140: 43-47.
Karadas M, Hatipoglu O. Efficacy of mouthwashes containing hydrogen peroxide on tooth whitening. ScientificWorldJournal 2015; 2015:961403 [doi: 10.1155/2015/961403].
De Andrade IC, Basting RT, Lima-Arsati YB, do Amaral FL, Rodrigues JA, França FM. Surface roughness evaluation and shade changes of a nanofilled resin composite after bleaching and immersion in staining solutions. Am J Dent 2011; 24: 245-249.
Moro AF, Prado M, Simao RA, Dias KR. Surface roughness of different composite resins subject to in-office bleaching. Gen Dent 2014; 62: 20-23.
Varanda E, Do Prado M, Simão RA, Dias KR. Effect of in-office bleaching agentes on the surface roughness and morphology of different dental composites: an AFM study. Microsc Res Tech 2013; 76: 481-485.
Schuster L, Reichl FX, Rothmund L, He X, et al. Effect of Opalescence(®) bleaching gels on the elution of bulk-fill composite components. Dent Mater 2016; 32:127-135.
Reis A, Dalanhol AP, Cunha TS, Kossatz, Loguercio AD. Assessment of tooth sensitivity before light-activated bleaching using a desensitizer. Oper Dent 2011; 36: 12-17.
Demarco FF, Meireles SS, Masotti AS. Over-the-counter whitening agents: a concise review. Braz Oral Res 2009; 23 Suppl 1: 64-70.
Miranda D de A, Bertoldo CE, Aguiar FH, Lima DA, Lovadino JR. Effects of mouthwashes on Knoop hardness and surface roughness of dental composites after different immersion times. Braz Oral Res 2011; 25: 168-173.
Fernandes FP, Turssi CP, França FMG, Basting RT, Amaral FLB. Whitening mouthwash containing hydrogen peroxide decreases enamel microhardness in vitro. BJOS 2017; 16: 1-9. DOI: 10.20396/bjosv16i0.8650504.
Jaime IM, França FM, Basting RT, Turssi CP, Amaral FL. Efficacy of hydrogen-peroxide-based mouthwash in altering enamel color. Am J Dent 2014; 27: 47-50.
Rigo LC, Bordin D, Fardin VP, Coelho PG, Bromage TG, Reis A, Hirata R. Influence of polishing system on the surface roughness of flowable and regular-viscosity bulk fill composites. Int J Periodontics Restorative Dent 2018; 38:e79–e86.
Gurgan S, Yalcin F. The effect of two different bleaching regimens on the surface roughness and hardness of toothcolored restorative materials. Quintessence Int 2007; 38: 83-87.
Wang L, Francisconi LF, Atta MT, Dos Santos JR, Del Padre NC, Gonini A Jr, Fernandes KB Effect of bleaching gels on surface roughness of nanofilled composite resins. Eur J Dent 2011; 5: 173-179.
Rattacaso RM, da Fonseca Roberti Garcia L, Aguilar FG, Consani S, Pires de Souza FCP. Bleaching agent action on color stability, surface roughness and microhardness of composites submitted to accelerated artificial aging. Eur J Dent 2011; 5: 145-149.
Shah MB, Ferracane JL, Kruzic JJ. R-curve behavior and toughening mechanisms of resin-based dental composites: effects of hydration and post- cure heat treatment. Dent Mater 2009; 25: 760-770.
Alshali RZ, Salim NA, Satterthwaite JD, Silikas N. Longterm sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva. J Dent 2015; 43: 1511-1518.
Vichi A, Ferrari M, Davidson CL. Color and opacity variations in three diferente resin-based composite products after water aging. Dent Mater 2004; 20: 530-534.
Topcu FT, Sahinkesen G, Yamanel K, Erdemir U, Oktay EA, Ersahan S. Influence of different drinks on the colour stability of dental resin composites. Eur J Dent 2009; 3: 50-56.
Özduman ZC, Kazak M, Fildisi MA, Özlen RH, Dalkilic E, Donmez N. Effect of polymerization time and home bleaching agent on the microhardness and surface roughness of bulk-fill composites: a scanning electron microscopy study. Scanning 2019; 2019:2307305 [doi: 10.1155/2019/2307305].
Mansouri SA, Zidan AZ. Effect of water sorption and solubility on color stability of bulk-fill resin composite. J Contemp Dent Pract 2018; 19: 1129-1134.
Van Landuyt KL, Snauwaert J, De Munck J, Peumans M, et al. Systematic review of the chemical composition of contemporary dental adhesives. Biomaterials 2007; 28: 3757-3785.
Um CM, Ruyter IE. Staining of resin-based veneering materials with coffee and tea. Quintessence Int 1991; 22: 377-386.
Schulze KA, Marshall SJ, Gansky SA, Marshall GW. Color stability and hardness in dental composites after accelerated aging. Dent Mater 2003; 19: 612-619.
Janda R, Roulet JF, Latta M, Steffin G, Ruttermann S. Color stability of resin-based filling materials after aging when cured with plasma or halogen light. Eur J Oral Sci 2005; 113: 251-257.
Geurtsen W, Leyhausen G, Garcia-Godoy F. Effect of storage media on the fluoride release and surface microhardness of four polyacid-modified composite resins (“compomers”). Dent Mater 1999; 15:196-201.
Lopes LS, Helio Filho HRS, Albuquerque EG, Tardem C, Miranda MS, Barceleiro MO. How do the optical properties of the bulk fill posterior composites change after 2 years of simulated toothbrushing? Braz Dent Sci 2019; 22: 378-386.
فهرسة مساهمة: Keywords: bleaching agents; composite resins; surface properties
Local Abstract: [Publisher, Portuguese] Este estudo in vitro teve objetivo de avaliar o efeito de protocolos clareadores sobre a rugosidade de superfície (Ra), alteração de cor e micromorfologia de resina bulk-fill de baixa viscosidade (Filtek Bulk Fill Flow, 3M ESPE), alta viscosidade (Filtek Bulk Fill, 3M ESPE) e de uma resina composta nanoparticulada (controle) (Filtek Z350 XT, 3M ESPE). Quarenta amostras de cada resin composta (discos de 5 mm de diâmetro e 2 mm de espessura) foram aleatoriamente divididas em quatro grupos , de acordo com protocolo clareador (n=10): a) Gel de peróxido de carbamida (Opalescence, Ultradent Products) (2 horas/dia, por 14 dias); b) Gel de peróxido de hidrogênio (Opalescence Boost, Ultradent Products) (3 sessões de clareamento, uma por semana, 45 min/sessão); enxaguatório clareador (Listerine Whitening Extreme, Johnson & Johnson) (2 min/dia, por 14 dias); d) água destilada (controle). As amostras foram submetidas a leituras, em triplicata (Ra e cor (parâmetros CIELab) antes e depois do contato com os protocolos clareadores. A micromorfologia de superfície foi conduzida em microscópio eletrônico de varredura (MEV). Ra e parâmetros de cor (ΔL, Δa, Δb e ΔE) foram analisados por modelos lineares generalizados (α=0.05). A Ra da resina bulk-fill de alta viscosidade foi significantemente superior do que para os outros compósitos (p<0.05). A Ra aumentou significantemente (p<0.05) e a superfície ficou mais irregular (MEV) para todos os compósitos, independente do protocolo clareador (p<0,05). A resina bulk-fill de alta viscosidade obteve menor ΔE (p<0.05) do que a resina composta nanoparticulada, imersa em água destilada. Pode-se concluir que as características de cada resina composta influenciaram de forma mais significativa a Ra do que o protocolo clareador. A resina bulk fill de alta viscosidade apresentou menor alteração de cor.
المشرفين على المادة: 0 (Composite Resins)
0 (Filtek Z250)
0 (Tooth Bleaching Agents)
0 (filtek Z350)
BBX060AN9V (Hydrogen Peroxide)
تواريخ الأحداث: Date Created: 20200913 Date Completed: 20200922 Latest Revision: 20200922
رمز التحديث: 20221213
PMID: 32920607
قاعدة البيانات: MEDLINE