دورية أكاديمية

Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles.

التفاصيل البيبلوغرافية
العنوان: Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles.
المؤلفون: Nenen F, Garnica N, Rojas V, Oyonarte R
المصدر: The Angle orthodontist [Angle Orthod] 2021 May 01; Vol. 91 (3), pp. 336-342.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Edward H. Angle Society of Orthodontia Country of Publication: United States NLM ID: 0370550 Publication Model: Print Cited Medium: Internet ISSN: 1945-7103 (Electronic) Linking ISSN: 00033219 NLM ISO Abbreviation: Angle Orthod Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Appleton, Wis. [etc.] Edward H. Angle Society of Orthodontia.
مواضيع طبية MeSH: Orthodontic Anchorage Procedures*, Animals ; Bone Screws ; Orthodontic Appliance Design ; Swine ; Titanium ; Torque
مستخلص: Objectives: To compare the primary stability of miniscrews after repeated cycles of insertion through insertion torque (IT) measurements and resonance frequency analysis (RFA).
Materials and Methods: Sixty titanium miniscrews were divided into two groups according to the insertion protocol: one with predrilled sites and the other self-drilled into porcine iliac crest bone specimens. Each group had three cycles of reinsertion. After each insertion, the IT and RFA were measured. The IT was measured by using a torque meter, and the RFA was measured using the Osstell ISQ device. A total of five miniscrews of each group were selected for sequential assessment of the morphology of their tip and threads using scanning electron microscopy after each insertion cycle.
Results: No statistically significant differences were found in the IT values of miniscrews reinserted up to three times in the group with predrilled surgical sites. The IT value increased significantly with the number of reinsertions in the self-drilled group. The RFA value decreased as the number of insertions increased in both groups.
Conclusions: Under the conditions of this in vitro study, reinserting miniscrews deteriorates the integrity of their tip and thread. Reinsertion should be discouraged particularly when insertion sites are not predrilled.
(© 2021 by The EH Angle Education and Research Foundation, Inc.)
References: Eur J Orthod. 2018 Jan 23;40(1):37-44. (PMID: 28449060)
Clin Oral Implants Res. 2006 Feb;17(1):109-14. (PMID: 16441792)
Int J Dent. 2014;2014:424923. (PMID: 25136368)
Am J Orthod Dentofacial Orthop. 2018 Jan;153(1):54-60. (PMID: 29287652)
Periodontol 2000. 2008;47:51-66. (PMID: 18412573)
Am J Orthod Dentofacial Orthop. 2017 Aug;152(2):224-231. (PMID: 28760284)
Int J Oral Maxillofac Implants. 2009 Jul-Aug;24(4):647-54. (PMID: 19885404)
Am J Orthod Dentofacial Orthop. 2018 Apr;153(4):505-511. (PMID: 29602342)
Am J Orthod Dentofacial Orthop. 2010 May;137(5):588.e1-5; discussion 588-9. (PMID: 20451776)
J Oral Rehabil. 2013 Mar;40(3):221-7. (PMID: 23278128)
Korean J Orthod. 2017 Jul;47(4):238-247. (PMID: 28670565)
Angle Orthod. 2013 Mar;83(2):230-8. (PMID: 22931201)
Clin Implant Dent Relat Res. 2009 Mar;11(1):52-8. (PMID: 18384400)
Clin Oral Implants Res. 1996 Sep;7(3):261-7. (PMID: 9151590)
Angle Orthod. 2019 Mar;89(2):284-291. (PMID: 30382751)
Am J Orthod Dentofacial Orthop. 2012 Nov;142(5):596-614.e5. (PMID: 23116501)
Am J Orthod Dentofacial Orthop. 2009 Mar;135(3):284-91. (PMID: 19268825)
Am J Orthod Dentofacial Orthop. 2006 Nov;130(5):676-85. (PMID: 17110268)
Am J Orthod Dentofacial Orthop. 2017 Oct;152(4):483-488. (PMID: 28962732)
J Clin Orthod. 1997 Nov;31(11):763-7. (PMID: 9511584)
Angle Orthod. 2013 Jul;83(4):674-9. (PMID: 23244461)
J Oral Maxillofac Surg. 2010 Nov;68(11):2682-9. (PMID: 20869150)
Am J Orthod Dentofacial Orthop. 2014 Apr;145(4):480-5. (PMID: 24703286)
J Clin Orthod. 2002 Oct;36(10):592-6. (PMID: 12428309)
J Orofac Orthop. 2016 Jul;77(4):296-303. (PMID: 27272055)
J Clin Orthod. 2002 May;36(5):298-302. (PMID: 12056211)
J Orthod. 2011 Mar;38(1):15-20. (PMID: 21367824)
Int J Oral Maxillofac Implants. 2004 Jan-Feb;19(1):100-6. (PMID: 14982362)
Clin Orthod Res. 2000 Feb;3(1):23-8. (PMID: 11168281)
Eur J Orthod. 2014 Jun;36(3):303-13. (PMID: 23873818)
فهرسة مساهمة: Keywords: Insertion torque; Miniscrews; Reinsertion; Resonance frequency analysis
المشرفين على المادة: D1JT611TNE (Titanium)
تواريخ الأحداث: Date Created: 20201230 Date Completed: 20210510 Latest Revision: 20210510
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC8084464
DOI: 10.2319/050120-375.1
PMID: 33378455
قاعدة البيانات: MEDLINE
الوصف
تدمد:1945-7103
DOI:10.2319/050120-375.1