دورية أكاديمية

Quantification of Myocardial Creatine and Triglyceride Content in the Human Heart: Precision and Accuracy of in vivo Proton Magnetic Resonance Spectroscopy.

التفاصيل البيبلوغرافية
العنوان: Quantification of Myocardial Creatine and Triglyceride Content in the Human Heart: Precision and Accuracy of in vivo Proton Magnetic Resonance Spectroscopy.
المؤلفون: Bakermans AJ; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Boekholdt SM; Department of Cardiology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., de Vries DK; Department of Experimental Cardiology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Reckman YJ; Department of Experimental Cardiology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Farag ES; Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., de Heer P; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.; C.J. Gorter Center for High Field MR, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands., Uthman L; Laboratory of Experimental Intensive Care and Anesthesiology, Department of Anesthesiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Denis SW; Laboratory Genetic Metabolic Diseases, Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Zuurbier CJ; Laboratory of Experimental Intensive Care and Anesthesiology, Department of Anesthesiology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Houtkooper RH; Laboratory Genetic Metabolic Diseases, Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Koolbergen DR; Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Kluin J; Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Planken RN; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Lamb HJ; Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands., Webb AG; C.J. Gorter Center for High Field MR, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands., Strijkers GJ; Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands., Beard DA; Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, Michigan, USA., Jeneson JAL; Neuroimaging Center, Department of Neuroscience, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands., Nederveen AJ; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
المصدر: Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2021 Aug; Vol. 54 (2), pp. 411-420. Date of Electronic Publication: 2021 Feb 10.
نوع المنشور: Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't
اللغة: English
بيانات الدورية: Publisher: Wiley-Liss Country of Publication: United States NLM ID: 9105850 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-2586 (Electronic) Linking ISSN: 10531807 NLM ISO Abbreviation: J Magn Reson Imaging Subsets: MEDLINE
أسماء مطبوعة: Publication: <2005-> : Hoboken , N.J. : Wiley-Liss
Original Publication: Chicago, IL : Society for Magnetic Resonance Imaging, c1991-
مواضيع طبية MeSH: Creatine* , Myocardium*, Heart/diagnostic imaging ; Humans ; Proton Magnetic Resonance Spectroscopy ; Triglycerides
مستخلص: Background: Proton magnetic resonance spectroscopy ( 1 H-MRS) of the human heart is deemed to be a quantitative method to investigate myocardial metabolite content, but thorough validations of in vivo measurements against invasive techniques are lacking.
Purpose: To determine measurement precision and accuracy for quantifications of myocardial total creatine and triglyceride content with localized 1 H-MRS.
Study Type: Test-retest repeatability and measurement validation study.
Subjects: Sixteen volunteers and 22 patients scheduled for open-heart aortic valve replacement or septal myectomy.
Field Strength/sequence: Prospectively ECG-triggered respiratory-gated free-breathing single-voxel point-resolved spectroscopy (PRESS) sequence at 3 T.
Assessment: Myocardial total creatine and triglyceride content were quantified relative to the total water content by fitting the 1 H-MR spectra. Precision was assessed with measurement repeatability. Accuracy was assessed by validating in vivo 1 H-MRS measurements against biochemical assays in myocardial tissue from the same subjects.
Statistical Tests: Intrasession and intersession repeatability was assessed using Bland-Altman analyses. Agreement between 1 H-MRS measurements and biochemical assay was tested with regression analyses.
Results: The intersession repeatability coefficient for myocardial total creatine content was 41.8% with a mean value of 0.083% ± 0.020% of the total water signal, and 36.7% for myocardial triglyceride content with a mean value of 0.35% ± 0.13% of the total water signal. Ex vivo myocardial total creatine concentrations in tissue samples correlated with the in vivo myocardial total creatine content measured with 1 H-MRS: n = 22, r = 0.44; P < 0.05. Likewise, ex vivo myocardial triglyceride concentrations correlated with the in vivo myocardial triglyceride content: n = 20, r = 0.50; P < 0.05.
Data Conclusion: We validated the use of localized 1 H-MRS of the human heart at 3 T for quantitative assessments of in vivo myocardial tissue metabolite content by estimating the measurement precision and accuracy.
Level of Evidence: 2 TECHNICAL EFFICACY STAGE: 2.
(© 2021 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC. on behalf of International Society for Magnetic Resonance in Medicine.)
References: Lancet. 1986 Feb 8;1(8476):307-10. (PMID: 2868172)
J Am Coll Cardiol. 2008 Nov 25;52(22):1793-9. (PMID: 19022158)
Physiol Rep. 2020 Sep;8(17):e14543. (PMID: 32869950)
J Magn Reson Imaging. 2020 Jun;51(6):1679-1688. (PMID: 31799782)
J Clin Hypertens (Greenwich). 2009 Sep;11(9):528-32. (PMID: 19751469)
Front Physiol. 2017 Nov 27;8:939. (PMID: 29230178)
Magn Reson Med. 1994 Aug;32(2):175-80. (PMID: 7968439)
Am J Physiol. 1984 May;246(5 Pt 2):R665-77. (PMID: 6720989)
J Magn Reson. 1997 Nov;129(1):35-43. (PMID: 9405214)
J Appl Physiol (1985). 2002 Jun;92(6):2264-72. (PMID: 12015335)
Diabetes. 2007 Dec;56(12):2849-53. (PMID: 17717279)
J Mol Cell Cardiol. 1984 Nov;16(11):1023-36. (PMID: 6520874)
Heart Fail Rev. 2013 Sep;18(5):657-68. (PMID: 22945240)
Magn Reson Med. 2011 Sep;66(3):619-24. (PMID: 21721038)
Radiology. 1997 Aug;204(2):403-10. (PMID: 9240527)
Magn Reson Med. 2014 Nov;72(5):1201-7. (PMID: 24259469)
Am J Physiol Endocrinol Metab. 2005 Nov;289(5):E935-9. (PMID: 15972271)
J Clin Endocrinol Metab. 2006 Nov;91(11):4689-95. (PMID: 16926257)
Circ Cardiovasc Imaging. 2013 Sep;6(5):808-16. (PMID: 23833283)
Radiology. 2007 Oct;245(1):251-7. (PMID: 17885193)
Lancet. 1998 Mar 7;351(9104):714-8. (PMID: 9504516)
J Am Coll Cardiol. 2003 Nov 5;42(9):1587-93. (PMID: 14607443)
MAGMA. 2019 Apr;32(2):259-268. (PMID: 30377860)
Magn Reson Med. 2016 Jan;75(1):15-8. (PMID: 25753153)
Circulation. 1975 Jul;52(1):88-102. (PMID: 1169134)
NMR Biomed. 2014 Nov;27(11):1285-92. (PMID: 25181700)
Magn Reson Med. 2015 Jun;73(6):2069-74. (PMID: 24962369)
Magn Reson Med. 2011 May;65(5):1234-8. (PMID: 21500254)
Magn Reson Med. 2012 Dec;68(6):1696-704. (PMID: 22294511)
Circ Cardiovasc Imaging. 2011 Sep;4(5):558-65. (PMID: 21737602)
J Magn Reson Imaging. 2016 Nov;44(5):1151-1158. (PMID: 27016265)
Biochim Biophys Acta. 1993 Aug 11;1169(2):176-82. (PMID: 8343541)
NMR Biomed. 2021 May;34(5):e4350. (PMID: 32596978)
Magn Reson Med. 2003 Mar;49(3):417-23. (PMID: 12594743)
Eur J Radiol. 2010 Jun;74(3):e60-6. (PMID: 19406596)
J Magn Reson Imaging. 2019 Dec;50(6):1973-1981. (PMID: 31125172)
MAGMA. 2004 Mar;16(4):155-9. (PMID: 15042412)
Magn Reson Med. 1999 Nov;42(5):903-10. (PMID: 10542349)
معلومات مُعتمدة: R01 HL144657 United States HL NHLBI NIH HHS; 91617155 Nederlandse Organisatie voor Wetenschappelijk Onderzoek; Netherlands Organisation for Scientific Research; R01 HL144657 United States NH NIH HHS
فهرسة مساهمة: Keywords: biopsy; magnetic resonance spectroscopy; myectomy; myocardial metabolism; triglycerides; validation
المشرفين على المادة: 0 (Triglycerides)
MU72812GK0 (Creatine)
تواريخ الأحداث: Date Created: 20210211 Date Completed: 20210722 Latest Revision: 20210818
رمز التحديث: 20240628
مُعرف محوري في PubMed: PMC8277665
DOI: 10.1002/jmri.27531
PMID: 33569824
قاعدة البيانات: MEDLINE
الوصف
تدمد:1522-2586
DOI:10.1002/jmri.27531