دورية أكاديمية

Gross Trunnion Failure of a Type 1 Taper After Metal-on-Polyethylene Total Hip Arthroplasty: A Report of 2 Cases.

التفاصيل البيبلوغرافية
العنوان: Gross Trunnion Failure of a Type 1 Taper After Metal-on-Polyethylene Total Hip Arthroplasty: A Report of 2 Cases.
المؤلفون: Pagani NR; Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, Massachusetts., LeRoy TE, Menendez ME, Stoker GE, Lococo DV, Nairus JG
المصدر: JBJS case connector [JBJS Case Connect] 2021 Jun 24; Vol. 11 (2). Date of Electronic Publication: 2021 Jun 24.
نوع المنشور: Case Reports; Journal Article
اللغة: English
بيانات الدورية: Publisher: Wolters Kluwer Country of Publication: United States NLM ID: 101596828 Publication Model: Electronic Cited Medium: Internet ISSN: 2160-3251 (Electronic) Linking ISSN: 21603251 NLM ISO Abbreviation: JBJS Case Connect Subsets: MEDLINE
أسماء مطبوعة: Publication: 2016- : Philadelphia : Wolters Kluwer
Original Publication: Needham, MA : Journal of Bone & Joint Surgery, Inc.
مواضيع طبية MeSH: Arthroplasty, Replacement, Hip*/adverse effects , Hip Prosthesis*/adverse effects, Humans ; Male ; Polyethylene ; Prosthesis Design ; Prosthesis Failure ; United States
مستخلص: Case: We describe 2 cases of gross trunnion failure (GTF) in males with Centers for Disease Control and Prevention Class 3 obesity 10 years after metal-on-polyethylene total hip arthroplasty (THA) with a titanium-alloy femoral stem and Type 1 taper. One patient received a large diameter cobalt-chromium femoral head, whereas the other received a smaller diameter head, both with high-offset femoral stems.
Conclusion: This is the first report of GTF involving the Echo Bi-Metric femoral stem after metal-on-polyethylene THA, and surgeons should consider the potential complication of GTF when using this specific femoral stem with metal heads in obese male patients.
Competing Interests: Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSCC/B537).
(Copyright © 2021 by The Journal of Bone and Joint Surgery, Incorporated.)
References: Heim CS, Greenwald AS. The rationale and performance of modularity in total hip arthroplasty. Orthopedics. 2005;28(9 suppl):s1113-5.
Weiser MC, Lavernia CJ. Trunnionosis in total hip arthroplasty. J Bone Joint Surg Am. 2017;99(17):1489-501.
Gilbert JL, Buckley CA, Jacobs JJ. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res. 1993;27(12):1533-44.
Berstock JR, Whitehouse MR, Duncan CP. Trunnion corrosion: what surgeons need to know in 2018. Bone Joint J. 2018;100-B(1):44-9.
Mistry JB, Chughtai M, Elmallah RK, Diedrich A, Le S, Thomas M, Mont MA. Trunnionosis in total hip arthroplasty: a review. J Orthop Traumatol. 2016;17(1):1-6.
Fitz D, Klemt C, Chen W, Xiong L, Yeo I, Kwon YM. Head-neck taper corrosion in metal-on-polyethylene total hip arthroplasty: risk factors, clinical evaluation, and treatment of adverse local tissue reactions. J Am Acad Orthop Surg. 2020;28(22):907-13.
Cooper HJ, Della Valle CJ, Berger RA, Tetreault M, Paprosky WG, Sporer SM, Jacobs JJ. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012;94(18):1655-61.
Bansal T, Aggarwal S, Dhillon MS, Patel S. Gross trunnion failure in metal on polyethylene total hip arthroplasty—a systematic review of literature. Int Orthop. 2020;44(4):609-21.
Bolarinwa SA, Martino JM, Moskal JT, Wolfe MW, Shuler TE. Gross trunnion failure after a metal-on-polyethylene total hip arthroplasty leading to dissociation at the femoral head-trunnion interface. Arthroplast Today. 2019;5(1):5-10.
Matsen Ko L, Chen AF, Deirmengian GK, Hozack WJ, Sharkey PF. Catastrophic femoral head-stem trunnion dissociation secondary to corrosion. J Bone Joint Surg Am. 2016;98(16):1400-4.
Banerjee S, Cherian JJ, Bono JV, Kurtz SM, Geesink R, Meneghini RM, Delanois RE, Mont MA. Gross trunnion failure after primary total hip arthroplasty. J Arthroplasty. 2015;30(4):641-8.
Talmo CT, Sharp KG, Malinowska M, Bono JV, Ward DM, Lareau J. Spontaneous modular femoral head dissociation complicating total hip arthroplasty. Orthopedics. 2014;37(6):e592-5.
Morlock MM, Bünte D, Ettema H, Verheyen CC, Hamberg Å, Gilbert J. Primary hip replacement stem taper fracture due to corrosion in 3 patients. Acta Orthop. 2016;87(2):189-92.
Triantafyllopoulos GK, Elpers ME, Burket JC, Esposito CI, Padgett DE, Wright TM. Otto Aufranc Award: large heads do not increase damage at the head-neck taper of metal-on-polyethylene total hip arthroplasties. Clin Orthop Relat Res. 2016;474(2):330-8.
Whitehouse MR, Endo M, Zachara S, Nielsen TO, Greidanus NV, Masri BA, Garbuz DS, Duncan CP. Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion: the risk of misdiagnosis. Bone Joint J. 2015;97-B(8):1024-30.
Meding JB, Keating EM, Ritter MA, Faris PM, Berend ME. Minimum ten-year follow-up of a straight-stemmed, plasma-sprayed, titanium-alloy, uncemented femoral component in primary total hip arthroplasty. J Bone Joint Surg Am. 2004;86-A(1):92-7.
Sueyoshi T, Berend ME, Meding JB, Malinzak RA, Lackey WG, Ritter MA. Changes in femoral stem geometry reduce intraoperative femoral fracture rates in total hip replacement. Open J Orthop. 2015;5(5):115-9.
Donaldson FE, Coburn JC, Siegel KL. Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters. J Biomech. 2014;47(7):1634-41.
Matharu GS, Pandit HG, Murray DW, Judge A. Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMC Musculoskelet Disord. 2016;17(1):1-12.
Raju S, Chinnakkannu K, Puttaswamy MK, Phillips MJ. Trunnion corrosion in metal-on-polyethylene total hip arthroplasty: a case series. J Am Acad Orthop Surg. 2017;25(2):133-9.
Del Balso C, Teeter MG, Tan SC, Lanting BA, Howard JL. Taperosis: does head length affect fretting and corrosion in total hip arthroplasty? Bone Jt J. 2015;97-B(7):911-6.
Morlock MM, Dickinson EC, Günther KP, Bünte D, Polster V. Head taper corrosion causing head bottoming out and consecutive gross stem taper failure in total hip arthroplasty. J Arthroplasty. 2018;33(11):3581-90.
Higgs GB, MacDonald DW, Gilbert JL, Rimnac CM, Kurtz SM; Implant Research Center Writing Committee. Does taper size have an effect on taper damage in retrieved metal-on-polyethylene total hip devices? J Arthroplasty. 2016;31(9):277-81.
Tan SC, Teeter MG, Del Balso C, Howard JL, Lanting BA. Effect of taper design on trunnionosis in metal on polyethylene total hip arthroplasty. J Arthroplasty. 2015;30(7):1269-72.
Kao YY, Koch CN, Wright TM, Padgett DE. Flexural rigidity, taper angle, and contact length Affect fretting of the femoral stem trunnion in total hip arthroplasty. J Arthroplasty. 2016;31(9):254-8.
Nassif NA, Nawabi DH, Stoner K, Elpers M, Wright T, Padgett DE. Taper design affects failure of large-head metal-on-metal total hip replacements. Clin Orthop Relat Res. 2014;472:564-71.
Kocagoz SB, Underwood RJ, Macdonald DW, Gilbert JL, Kurtz SM. Ceramic heads decrease metal release caused by head-taper fretting and corrosion. Clin Orthop Relat Res. 2016;474(4):985-94.
Kurtz SM, Kocagöz SB, Hanzlik JA, Underwood RJ, Gilbert JL, MacDonald DW, Lee GC, Mont MA, Kraay MJ, Klein GR, Parvizi J, Rimnac CM. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Clin Orthop Relat Res. 2013;471(10):3270-82.
المشرفين على المادة: 9002-88-4 (Polyethylene)
تواريخ الأحداث: Date Created: 20210624 Date Completed: 20220401 Latest Revision: 20230809
رمز التحديث: 20240628
DOI: e21.00098
PMID: 34166254
قاعدة البيانات: MEDLINE
الوصف
تدمد:2160-3251