Expect the Unexpected: Artifacts From Lodged 124I Capsule in Esophagus on PET/CT.

التفاصيل البيبلوغرافية
العنوان: Expect the Unexpected: Artifacts From Lodged 124I Capsule in Esophagus on PET/CT.
المؤلفون: Chua WM; From the Division of Radiological Sciences, Department of Nuclear Medicine and Molecular Imaging, Singapore General Hospital., Tang CYL; From the Division of Radiological Sciences, Department of Nuclear Medicine and Molecular Imaging, Singapore General Hospital., Tham WY, Yang SP, Tay YS; From the Division of Radiological Sciences, Department of Nuclear Medicine and Molecular Imaging, Singapore General Hospital., Loke KSH
المصدر: Clinical nuclear medicine [Clin Nucl Med] 2022 Jun 01; Vol. 47 (6), pp. 547-548. Date of Electronic Publication: 2022 Jan 12.
نوع المنشور: Case Reports; Journal Article
اللغة: English
بيانات الدورية: Publisher: Lippincott Country of Publication: United States NLM ID: 7611109 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1536-0229 (Electronic) Linking ISSN: 03639762 NLM ISO Abbreviation: Clin Nucl Med Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Philadelphia, Lippincott.
مواضيع طبية MeSH: Iodine Radioisotopes* , Positron Emission Tomography Computed Tomography*/methods, Artifacts ; Esophagus/diagnostic imaging ; Female ; Humans ; Middle Aged ; Positron-Emission Tomography/methods
مستخلص: Abstract: A 61-year-old woman with well-differentiated thyroid cancer underwent 124I-PET/CT imaging. A 124I capsule was administered orally, and the patient was imaged 90 minutes after from the skull vertex to feet. The 124I capsule was unexpectedly lodged in the esophagus. We illustrate attenuation and scatter correction artifacts from 124I capsule unexpectedly lodged in the esophagus and the usefulness of nonattenuation correction images in such circumstances. This also highlights the importance of drinking adequate amounts of water following the ingestion of iodine capsules (123I, 124I, or 131I) to reduce the resulting radiation dose to the esophagus.
Competing Interests: Conflicts of interest and sources of funding: National University Cancer Institute, Singapore (NCIS) Centre Grant Seed Funding Program and SINGHEALTH DUKE-NUS Radiological Sciences Academic Clinical Programme (grant). The authors declare no conflicts of interest.
(Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.)
References: Wangerin KA, Baratto L, Khalighi MM, et al. Clinical evaluation of 68 Ga-PSMA-II and 68 Ga-RM2 PET images reconstructed with an improved scatter correction algorithm. AJR Am J Roentgenol . 2018;211:655–660.
Lubberink M, Herzog H. Quantitative imaging of 124 I and 86 Y with PET. Eur J Nucl Med Mol Imaging . 2011;38 suppl 1(suppl 1):S10–S18.
Pentlow KS, Finn RD, Larson SM, et al. Quantitative imaging of yttrium-86 with PET. The occurrence and correction of anomalous apparent activity in high density regions. Clin Positron Imaging . 2000;3:85–90.
Conti M, Eriksson L. Physics of pure and non-pure positron emitters for PET: a review and a discussion. EJNMMI Phys . 2016;3:8.
Buchholz HG, Herzog H, Förster GJ, et al. PET imaging with yttrium-86: comparison of phantom measurements acquired with different PET scanners before and after applying background subtraction. Eur J Nucl Med Mol Imaging . 2003;30:716–720.
المشرفين على المادة: 0 (Iodine Radioisotopes)
0 (Iodine-124)
0 (Iodine-131)
تواريخ الأحداث: Date Created: 20220113 Date Completed: 20220506 Latest Revision: 20230925
رمز التحديث: 20231215
DOI: 10.1097/RLU.0000000000004046
PMID: 35025804
قاعدة البيانات: MEDLINE
الوصف
تدمد:1536-0229
DOI:10.1097/RLU.0000000000004046