تقرير
Cystoid Macular Edema 18 Years after Anterior Chamber Phakic Intraocular Lens Implantation.
العنوان: | Cystoid Macular Edema 18 Years after Anterior Chamber Phakic Intraocular Lens Implantation. |
---|---|
المؤلفون: | Warrak EL; Department of Ophthalmology and Visual Sciences, University of Balamand, Advanced Eye Care Hospital, Lebanon., Haddam MS; Department of Ophthalmology and Visual Sciences, University of Balamand, Advanced Eye Care Hospital, Lebanon., Dandan WN; Department of Ophthalmology and Visual Sciences, University of Balamand, Advanced Eye Care Hospital, Lebanon., Warrak JE; University of Balamand, Faculty of Medicine and Health Sciences, Lebanon., Sammouh FK; Department of Ophthalmology and Visual Sciences, University of Balamand, Advanced Eye Care Hospital, Lebanon. |
المصدر: | Case reports in ophthalmological medicine [Case Rep Ophthalmol Med] 2022 Jun 16; Vol. 2022, pp. 1853248. Date of Electronic Publication: 2022 Jun 16 (Print Publication: 2022). |
نوع المنشور: | Case Reports |
اللغة: | English |
بيانات الدورية: | Publisher: Hindawi Pub. Corp Country of Publication: United States NLM ID: 101581018 Publication Model: eCollection Cited Medium: Print ISSN: 2090-6722 (Print) NLM ISO Abbreviation: Case Rep Ophthalmol Med Subsets: PubMed not MEDLINE |
أسماء مطبوعة: | Original Publication: New York, NY : Hindawi Pub. Corp. |
مستخلص: | We report a case of a 54-year-old female patient who underwent PAC-IOL implantation 18 years prior to presentation. The patient had a best corrected visual acuity (BCVA) 20/20 in the right eye (OD) postoperatively with normal eye exam on routine follow-up since then. The patient presented for acute onset decreased visual acuity in the right eye. BCVA was 20/60, and exam showed blunted macular reflex with no evidence of inflammation. Optical coherence tomography (OCT) showed CME. She was started on topical treatment (ketorolac 0.5%) OD four times daily. Three weeks later, the patient had a BCVA of 20/20 OD with a normal macular reflex and an OCT showing the resolution of the CME. To our knowledge, this is the first reported case of a CME 18 years post PAC-IOL implantation. The possible cause of this incidence could be related to subclinical intraocular inflammation. Ophthalmologists should be aware of the possibility of such a latent CME post-PAC-IOL implantation. Competing Interests: The authors report no conflicts of interest in this work. (Copyright © 2022 Elias L. Warrak et al.) |
References: | Retina. 2016 Oct;36(10):1823-42. (PMID: 27328171) Can J Ophthalmol. 2016 Apr;51(2):83-6. (PMID: 27085263) Ophthalmology. 2009 Nov;116(11):2244-58. (PMID: 19883852) Case Rep Ophthalmol. 2015 Jul 08;6(2):223-7. (PMID: 26265909) Eur J Ophthalmol. 2011;21 Suppl 6:S10-9. (PMID: 23264324) J Int Med Res. 2019 Jan;47(1):188-195. (PMID: 30270801) Surv Ophthalmol. 2002 Aug;47 Suppl 1:S203-18. (PMID: 12204717) Am J Ophthalmol. 1989 Jun 15;107(6):659-63. (PMID: 2729412) Ann Ottalmol Clin Ocul. 1954 Feb;80(2):75-82. (PMID: 13171764) Trans Ophthalmol Soc U K (1962). 1959;79:393-424. (PMID: 13797034) Dev Ophthalmol. 2010;47:148-159. (PMID: 20703048) |
تواريخ الأحداث: | Date Created: 20220627 Latest Revision: 20220716 |
رمز التحديث: | 20231215 |
مُعرف محوري في PubMed: | PMC9225911 |
DOI: | 10.1155/2022/1853248 |
PMID: | 35757521 |
قاعدة البيانات: | MEDLINE |
تدمد: | 2090-6722 |
---|---|
DOI: | 10.1155/2022/1853248 |