Upside-down positioning of a peri-interventional cava filter during endovascular thrombectomy of a septic superior vena cava thrombosis.

التفاصيل البيبلوغرافية
العنوان: Upside-down positioning of a peri-interventional cava filter during endovascular thrombectomy of a septic superior vena cava thrombosis.
المؤلفون: Rosenov A; Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland., Haine A; Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland., Walti LN; Department of Infectious Diseases, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland., Capiaghi D; Department of General Internal Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland., Schindewolf M; Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland., Baumgartner I; Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
المصدر: SAGE open medical case reports [SAGE Open Med Case Rep] 2022 Aug 08; Vol. 10, pp. 2050313X221117333. Date of Electronic Publication: 2022 Aug 08 (Print Publication: 2022).
نوع المنشور: Case Reports
اللغة: English
بيانات الدورية: Publisher: SAGE Publications Country of Publication: England NLM ID: 101638686 Publication Model: eCollection Cited Medium: Print ISSN: 2050-313X (Print) Linking ISSN: 2050313X NLM ISO Abbreviation: SAGE Open Med Case Rep Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: [London] : SAGE Publications, 2013-
مستخلص: A 43-year-old male patient with advanced colon carcinoma presented with disseminated staphylococcus aureus bacteremia and central venous catheter associated septic thrombosis of the superior vena cava. Despite appropriate antimicrobial therapy and surgical debridement of distant foci, bacteremia persisted, so an endovascular thrombectomy was performed. Contrary to the usual application, the Capturex® peri-interventional cava filter was positioned upside down, in the direction of the blood flow, in the superior vena cava to prevent septic embolism during mechanical thrombectomy. The wall-adherent septic thrombus was mechanically detached using a RAT fragmentation basket® followed by Aspirex® rotational thrombectomy. Final phlebography showed complete thrombus removal. Small thrombus fragments could be demonstrated in the filter after retrieval. The adapted technique of a reverse positioning of the Capturex® filter in the superior vena cava seems feasible and effective.
Competing Interests: Declaration of conflicting interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
(© The Author(s) 2022.)
References: Ann Surg. 1985 Nov;202(5):653-8. (PMID: 4051612)
Open Forum Infect Dis. 2018 Oct 01;5(10):ofy249. (PMID: 30377625)
Open Respir Med J. 2012;6:14-9. (PMID: 22611460)
Vasc Endovascular Surg. 2019 May;53(4):351-354. (PMID: 30827200)
Surgery. 1995 Jul;118(1):49-53. (PMID: 7604379)
Br J Anaesth. 2011 Jan;106(1):65-8. (PMID: 20952425)
Hematology Am Soc Hematol Educ Program. 2014 Dec 5;2014(1):306-11. (PMID: 25696870)
J Endovasc Surg. 1999 Nov;6(4):365-9. (PMID: 10893141)
Am J Ther. 2014 Mar-Apr;21(2):131-6. (PMID: 22198069)
EJVES Vasc Forum. 2020 Sep 19;49:16-19. (PMID: 33089223)
Eur J Pharmacol. 2007 Feb 28;557(2-3):93-8. (PMID: 17222406)
Thromb Res. 2008;122(4):442-9. (PMID: 17850850)
Thromb J. 2005 Aug 22;3:11. (PMID: 16111500)
JRSM Cardiovasc Dis. 2020 Nov 30;9:2048004020976256. (PMID: 33294173)
Vasc Endovascular Surg. 2018 Nov;52(8):641-647. (PMID: 29898647)
فهرسة مساهمة: Keywords: Cava filter; endovascular therapy; septic thrombophlebitis; septic thrombosis; superior vena cava; thrombectomy
تواريخ الأحداث: Date Created: 20220815 Latest Revision: 20220816
رمز التحديث: 20240628
مُعرف محوري في PubMed: PMC9364187
DOI: 10.1177/2050313X221117333
PMID: 35966122
قاعدة البيانات: MEDLINE
الوصف
تدمد:2050-313X
DOI:10.1177/2050313X221117333