دورية أكاديمية

CORP: Sources and degrees of variability in whole animal intermittent hypoxia experiments.

التفاصيل البيبلوغرافية
العنوان: CORP: Sources and degrees of variability in whole animal intermittent hypoxia experiments.
المؤلفون: Zhang Z; Interdisciplinary Graduate Program in Molecular Medicine, University of Iowa, Iowa City, Iowa, United States.; Division of Hematology, Oncology, and Bone Marrow Transplantation, Department of Internal Medicine, University of Iowa, Iowa City, Iowa, United States., Kalra H; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States., Delzell MC; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States.; Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, Missouri, United States., Jedlicka CR; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States., Vasilyev M; Division of Hematology, Oncology, and Bone Marrow Transplantation, Department of Internal Medicine, University of Iowa, Iowa City, Iowa, United States., Vasileva A; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States., Tomasson MH; Interdisciplinary Graduate Program in Molecular Medicine, University of Iowa, Iowa City, Iowa, United States.; Division of Hematology, Oncology, and Bone Marrow Transplantation, Department of Internal Medicine, University of Iowa, Iowa City, Iowa, United States.; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States., Bates ML; Interdisciplinary Graduate Program in Molecular Medicine, University of Iowa, Iowa City, Iowa, United States.; Division of Hematology, Oncology, and Bone Marrow Transplantation, Department of Internal Medicine, University of Iowa, Iowa City, Iowa, United States.; Department of Health and Human Physiology, University of Iowa, Iowa City, Iowa, United States.; Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, Iowa, United States.
المصدر: Journal of applied physiology (Bethesda, Md. : 1985) [J Appl Physiol (1985)] 2023 May 01; Vol. 134 (5), pp. 1207-1215. Date of Electronic Publication: 2023 Mar 23.
نوع المنشور: Journal Article; Research Support, Non-U.S. Gov't; Research Support, N.I.H., Extramural
اللغة: English
بيانات الدورية: Publisher: American Physiological Society Country of Publication: United States NLM ID: 8502536 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1522-1601 (Electronic) Linking ISSN: 01617567 NLM ISO Abbreviation: J Appl Physiol (1985) Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Bethesda, MD : American Physiological Society, c1985-
مواضيع طبية MeSH: Hypoxia* , Oximetry*, Mice ; Animals ; Reproducibility of Results ; Disease Models, Animal ; Oxygen
مستخلص: Chamber exposures are commonly used to evaluate the physiological and pathophysiological consequences of intermittent hypoxia in animal models. Researchers in this field use both commercial and custom-built chambers in their experiments. The purpose of this Cores of Reproducibility in Physiology paper is to demonstrate potential sources of variability in these systems that researchers should consider. Evaluating the relationship between arterial oxygen saturation and inspired oxygen concentration, we found that there are important sex-dependent differences in the commonly used C57BL6/J mouse model. The time delay of the oxygen sensor that provides feedback to the system during the ramp-down and ramp-up phases was different, limiting the number of cycles per hour that can be conducted and the overall stability of the oxygen concentration. The time to reach the hypoxic and normoxic hold stages, and the overall oxygen concentration, were impacted by the cycle number. These variables were further impacted by whether there are animals present in the chamber, highlighting the importance of verifying the cycling frequency with animals in the chamber. At ≤14 cycles/h, instability in the chamber oxygen concentration did not impact arterial oxygen saturation but may be important at higher cycle numbers. Taken together, these data demonstrate the important sources of variability that justify reporting and verifying the target oxygen concentration, cycling frequency, and arterial oxygen concentration, particularly when comparing different animal models and chamber configurations. NEW & NOTEWORTHY Intermittent hypoxia exposures are commonly used in physiology and many investigators use chamber systems to perform these studies. Because of the variety of chamber systems and protocols used, it is important to understand the sources of variability in intermittent hypoxia experiments that can impact reproducibility. We demonstrate sources of variability that come from the animal model, the intermittent hypoxia protocol, and the chamber system that can impact reproducibility.
References: J Appl Physiol (1985). 2007 May;102(5):1927-35. (PMID: 17234796)
Respir Physiol Neurobiol. 2018 Oct;256:50-57. (PMID: 28549897)
Physiol Behav. 2013 Feb 17;110-111:87-95. (PMID: 23313562)
Gen Physiol Biophys. 2015 Jul;34(3):235-47. (PMID: 25816360)
Clin Hemorheol Microcirc. 2014;58(4):479-88. (PMID: 23514970)
PLoS One. 2017 Mar 31;12(3):e0174896. (PMID: 28362813)
Front Physiol. 2022 Jul 12;13:891005. (PMID: 35903067)
Front Physiol. 2018 Nov 06;9:1556. (PMID: 30459638)
Exp Physiol. 2007 Jan;92(1):87-97. (PMID: 17138622)
J Appl Physiol (1985). 2014 Oct 1;117(7):816-24. (PMID: 25080926)
Fed Proc. 1970 Jul-Aug;29(4):1524-32. (PMID: 5459901)
Respir Physiol Neurobiol. 2010 Feb 28;170(2):157-63. (PMID: 19969108)
J Appl Physiol (1985). 2016 May 15;120(10):1186-95. (PMID: 26917692)
Am J Physiol. 1958 Nov;195(2):424-8. (PMID: 13583188)
Exp Neurol. 2021 Jun;340:113672. (PMID: 33652030)
Physiology (Bethesda). 2014 Jan;29(1):39-48. (PMID: 24382870)
High Alt Med Biol. 2021 Mar;22(1):77-86. (PMID: 32960081)
Comp Biochem Physiol A Mol Integr Physiol. 2019 Dec;238:110543. (PMID: 31445081)
Am J Physiol Regul Integr Comp Physiol. 2019 May 1;316(5):R678-R686. (PMID: 30892915)
J Appl Physiol (1985). 2007 Jan;102(1):286-93. (PMID: 16916919)
Respir Physiol Neurobiol. 2016 Dec;234:47-59. (PMID: 27595979)
Neuroscience. 2019 Feb 1;398:55-63. (PMID: 30529693)
J Appl Physiol (1985). 2000 May;88(5):1907-14. (PMID: 10797156)
Biol Psychiatry. 2022 Feb 15;91(4):346-358. (PMID: 34130857)
Exp Physiol. 2007 Jan;92(1):79-85. (PMID: 17085676)
Am J Physiol Regul Integr Comp Physiol. 2014 Nov 15;307(10):R1181-97. (PMID: 25231353)
Front Physiol. 2019 May 22;10:609. (PMID: 31231229)
Handb Clin Neurol. 2022;188:103-123. (PMID: 35965023)
Am J Respir Crit Care Med. 2013 Mar 1;187(5):535-42. (PMID: 23220913)
Am J Physiol Lung Cell Mol Physiol. 2014 Jul 15;307(2):L129-40. (PMID: 24838748)
Hypoxia (Auckl). 2016 Apr 27;4:99-108. (PMID: 27800512)
Respir Physiol. 1998 May;112(2):123-34. (PMID: 9716296)
High Alt Med Biol. 2000 Summer;1(2):125-36. (PMID: 11256564)
Am J Physiol Cell Physiol. 2018 Nov 1;315(5):C766-C775. (PMID: 30183322)
Br J Nutr. 2018 Aug;120(s1):S1-S7. (PMID: 29081302)
J Appl Physiol (1985). 2000 Sep;89(3):1142-50. (PMID: 10956362)
Am J Physiol Regul Integr Comp Physiol. 2011 Jul;301(1):R131-9. (PMID: 21543638)
Auton Neurosci. 2013 Jan;173(1-2):22-7. (PMID: 23167993)
Life Sci. 2022 Feb 15;291:119340. (PMID: 33716067)
PLoS One. 2017 Jun 8;12(6):e0179444. (PMID: 28594929)
معلومات مُعتمدة: R56 HL152365 United States HL NHLBI NIH HHS; R56HL152365 United States NH NIH HHS
فهرسة مساهمة: Keywords: arterial oxygen saturation; chamber exposures; gas response kinetics; mouse models; sex as a biological variable
المشرفين على المادة: S88TT14065 (Oxygen)
تواريخ الأحداث: Date Created: 20230323 Date Completed: 20230427 Latest Revision: 20240502
رمز التحديث: 20240502
مُعرف محوري في PubMed: PMC10151045
DOI: 10.1152/japplphysiol.00643.2022
PMID: 36958346
قاعدة البيانات: MEDLINE
الوصف
تدمد:1522-1601
DOI:10.1152/japplphysiol.00643.2022