Editorial & Opinion

Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability.

التفاصيل البيبلوغرافية
العنوان: Limitations in using the EFLM WG-A/ISO approach for assessment of reagent lot variability.
المؤلفون: Bayat H; Clinical Laboratory Science, Sina Clinical Laboratory, Qaem Shahr, Iran., Johansen JV; Department of Metrology, Radiometer Medical ApS, Copenhagen, Denmark., Bachmann L; Department of Pathology, Virginia Commonwealth University, Richmond, USA., Person N; Siemens Healthineers USA, Chester Springs, USA.
المصدر: Clinical chemistry and laboratory medicine [Clin Chem Lab Med] 2023 Jun 01; Vol. 61 (11), pp. e215-e217. Date of Electronic Publication: 2023 Jun 01 (Print Publication: 2023).
نوع المنشور: Letter; Comment
اللغة: English
بيانات الدورية: Publisher: Walter De Gruyter Country of Publication: Germany NLM ID: 9806306 Publication Model: Electronic-Print Cited Medium: Internet ISSN: 1437-4331 (Electronic) Linking ISSN: 14346621 NLM ISO Abbreviation: Clin Chem Lab Med Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Berlin ; New York : Walter De Gruyter, c1998-
مواضيع طبية MeSH: Indicators and Reagents*/standards , Reagent Kits, Diagnostic*, Quality Control
التعليقات: Comment on: Clin Chem Lab Med. 2022 Feb 16;60(5):681-688. (PMID: 35172415)
Comment in: Clin Chem Lab Med. 2023 Jun 01;61(11):e218-e220. (PMID: 37261942)
References: van Schrojenstein Lantman, M, Çubukçu, HC, Boursier, G, Panteghini, M, Bernabeu-Andreu, FA, Milinkovic, N, et al.. on behalf of the European Federation of Clinical Chemistry, Laboratory Medicine EFLM Working Group Accreditation, ISO/CEN Standards WG-A/ISO . An approach for determining allowable between reagent lot variation. Clin Chem Lab Med 2022;60:681–8. https://doi.org/10.1515/cclm-2022-0083 . (PMID: 10.1515/cclm-2022-0083)
CLSI . User evaluation of between-reagent lot variation; approved guideline . CLSI document EP26-A. Wayne, PA: Clinical and Laboratory Standards Institute; 2013.
CLSI . User evaluation of acceptability of a reagent lot change . In: CLSI guideline EP26 , 2nd ed. Wayne, PA: Clinical and Laboratory Standards Institute; 2022.
Miller, WG, Erek, A, Cunningham, TD, Oladipo, O, Scott, MG, Johnson, RE. Commutability limitations influence quality control results with different reagent lots. Clin Chem 2011;57:76–83. https://doi.org/10.1373/clinchem.2010.148106 . (PMID: 10.1373/clinchem.2010.148106)
Kim, S, Chang, J, Kim, SK, Park, S, Huh, J, Jeong, TD. Sample size and rejection limits for detecting reagent lot variability: analysis of the applicability of the Clinical and Laboratory Standards Institute (CLSI) EP26-A protocol to real-world clinical chemistry data. Clin Chem Lab Med 2020;59:127–38. https://doi.org/10.1515/cclm-2020-0454 . (PMID: 10.1515/cclm-2020-0454)
فهرسة مساهمة: Keywords: CLSI EP26; lot-to-lot variation; measurement procedures; reagent-lot
المشرفين على المادة: 0 (Indicators and Reagents)
0 (Reagent Kits, Diagnostic)
تواريخ الأحداث: Date Created: 20230531 Date Completed: 20231004 Latest Revision: 20231004
رمز التحديث: 20240628
DOI: 10.1515/cclm-2023-0430
PMID: 37255006
قاعدة البيانات: MEDLINE
الوصف
تدمد:1437-4331
DOI:10.1515/cclm-2023-0430