Influence of Hand File Size on the Accuracy of Root ZX and iPex Electronic Apex Locators: An In Vitro Study.

التفاصيل البيبلوغرافية
العنوان: Influence of Hand File Size on the Accuracy of Root ZX and iPex Electronic Apex Locators: An In Vitro Study.
المؤلفون: Siddiqui AY; Department of Endodontics, King Abdulaziz University, Jeddah, SAU., Alothmani OS; Department of Endodontics, King Abdulaziz University, Jeddah, SAU.
المصدر: Cureus [Cureus] 2023 May 29; Vol. 15 (5), pp. e39662. Date of Electronic Publication: 2023 May 29 (Print Publication: 2023).
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Cureus, Inc Country of Publication: United States NLM ID: 101596737 Publication Model: eCollection Cited Medium: Print ISSN: 2168-8184 (Print) Linking ISSN: 21688184 NLM ISO Abbreviation: Cureus Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: Palo Alto, CA : Cureus, Inc.
مستخلص: Objective: To investigate the effect of the hand file size on the accuracy of Root ZX (J. Morita Co., Kyoto, Japan) and iPex (NSK, Tochigi, Japan).
Methods: Seventy-five single-rooted teeth were decoronated, and canals were coronally flared with Gates Glidden burs sizes 4, 3, and 2. Actual canal length was determined by averaging two readings obtained by inserting K-file size 8 until its tip was apparent at the most coronal border of the apical foramen. The reference length was actual length-0.5 mm. The blinded operator utilized Root ZX and iPex following the manufacturer's recommendations. Teeth were placed in sponge blocks soaked with Ringer's solution. Canals were irrigated with 5% sodium hypochlorite. K-file size 8 was attached to the lip clip and introduced until the APEX/0.0 mark, then withdrawn to the 0.5 mark. A stable meter gauge for five seconds indicated an acceptable reading. Readings with sizes 10 and 15 were obtained afterward. All measurements were done twice, then averaged. Data analysis was done using ANOVA and a posthoc Bonferroni test with the significance level set at  P <0.05.
Results: For Root ZX, the mean length with size 8 was not significantly different from the mean reference length ( P =0.205). The same was found for its mean length at size 10 ( P =0.093). However, the mean Root ZX length with size 15 was significantly shorter than the mean reference length ( P =0.019). Mean iPex lengths with sizes 8, 10, and 15 were all significantly shorter than the mean reference length ( P =0.038, 0.006, and 0.02, respectively).
Conclusion: The size of the hand file affected the precision of Root ZX and iPex.
Competing Interests: The authors have declared that no competing interests exist.
(Copyright © 2023, Siddiqui et al.)
References: J Endod. 2008 Jun;34(6):698-702. (PMID: 18498892)
Int Endod J. 2017 May;50(5):506-511. (PMID: 27079789)
Int Endod J. 2010 Sep;43(9):808-17. (PMID: 20796049)
Int Endod J. 2009 Apr;42(4):368-74. (PMID: 19220512)
J Endod. 2002 Aug;28(8):595-8. (PMID: 12184422)
Eur Endod J. 2019 Jul 10;4(2):75-79. (PMID: 32161891)
Int Endod J. 2013 Oct;46(10):904-9. (PMID: 23480176)
J Endod. 1994 Mar;20(3):111-4. (PMID: 7996080)
Int Endod J. 2007 May;40(5):362-73. (PMID: 17309741)
Int Endod J. 2005 Jan;38(1):36-45. (PMID: 15606822)
Int Endod J. 2005 Nov;38(11):827-33. (PMID: 16218976)
Int Endod J. 2004 Jul;37(7):425-37. (PMID: 15189431)
Aust Dent J. 2006 Jun;51(2):153-7. (PMID: 16848263)
Oral Surg Oral Med Oral Pathol. 1976 Jan;41(1):114-8. (PMID: 1061030)
J Endod. 2007 Apr;33(4):476-9. (PMID: 17368343)
J Endod. 2007 Aug;33(8):995-8. (PMID: 17878091)
Int Endod J. 1996 Nov;29(6):359-64. (PMID: 10332234)
J Endod. 1983 Mar;9(3):114-5. (PMID: 6590773)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 Aug;110(2):e57-61. (PMID: 20573531)
Braz Dent J. 2012;23(3):199-204. (PMID: 22814686)
J Endod. 2011 Sep;37(9):1306-9. (PMID: 21846555)
Int Endod J. 2013 Aug;46(8):769-74. (PMID: 23551276)
Int Endod J. 2006 Aug;39(8):595-609. (PMID: 16872454)
J Endod. 2012 Feb;38(2):236-9. (PMID: 22244644)
J Endod. 2002 Mar;28(3):160-2. (PMID: 12017171)
فهرسة مساهمة: Keywords: accuracy of apex locator; electronic apex locator measurements; hand file size; ipex; reference length; root zx
تواريخ الأحداث: Date Created: 20230531 Latest Revision: 20230601
رمز التحديث: 20240628
مُعرف محوري في PubMed: PMC10226783
DOI: 10.7759/cureus.39662
PMID: 37256168
قاعدة البيانات: MEDLINE
الوصف
تدمد:2168-8184
DOI:10.7759/cureus.39662