دورية أكاديمية

Bioequivalence of Two Tiotropium Dry Powder Inhalers and the Utility of Realistic Impactor Testing.

التفاصيل البيبلوغرافية
العنوان: Bioequivalence of Two Tiotropium Dry Powder Inhalers and the Utility of Realistic Impactor Testing.
المؤلفون: Gobetti C; Phargentis SA, Barbengo, Switzerland., Dissanayake S; Certior Consulting Ltd., London, United Kingdom., Shur J; Nanopharm Ltd., An Aptar Pharma Company, Newport, United Kingdom., Ganley W; Nanopharm Ltd., An Aptar Pharma Company, Newport, United Kingdom., Silva L; Nanopharm Ltd., An Aptar Pharma Company, Newport, United Kingdom., Salem I; International Pharmaceutical Research Center, Amman, Jordan., Najib O; International Pharmaceutical Research Center, Amman, Jordan., Harb U; International Pharmaceutical Research Center, Amman, Jordan.
المصدر: Journal of aerosol medicine and pulmonary drug delivery [J Aerosol Med Pulm Drug Deliv] 2023 Oct; Vol. 36 (5), pp. 257-267. Date of Electronic Publication: 2023 Jun 26.
نوع المنشور: Journal Article; Research Support, Non-U.S. Gov't
اللغة: English
بيانات الدورية: Publisher: Mary Ann Liebert, Inc Country of Publication: United States NLM ID: 101475057 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1941-2703 (Electronic) Linking ISSN: 19412711 NLM ISO Abbreviation: J Aerosol Med Pulm Drug Deliv
أسماء مطبوعة: Original Publication: Rochelle, NY : Mary Ann Liebert, Inc.
مواضيع طبية MeSH: Dry Powder Inhalers* , Lung*, Humans ; Tiotropium Bromide ; Administration, Inhalation ; Therapeutic Equivalency
مستخلص: Introduction: Inhaled antimuscarinics are a cornerstone of the management of chronic obstructive pulmonary disease. This article details a series of five pharmacokinetic (PK) studies comparing a generic tiotropium dry powder inhaler (DPI) to Spiriva HandiHaler, the realistic in vitro methods used to support those studies, and the related in vitro - in vivo correlations (IVIVCs). Methods: All five PK studies were of open-label, single-dose, crossover design with test and reference treatments administered to healthy subjects. Following unexpected results in the first three PK studies, a realistic impactor method was developed comprising an Oropharyngeal Consortium (OPC) mouth-throat and simulated inspiratory profiles in conjunction with a Next Generation Impactor (NGI). Mass fractions and the in vitro whole lung dose were estimated for the test product and Spiriva ® HandiHaler ® using this method, and IVIVCs derived. Results: Bioequivalence could not be demonstrated for C max in the first three PK studies (test/reference ratios ranging from 83.1% to 131.8%), although was observed for AUC t . Reanalysis of the corresponding biobatches with the realistic NGI method revealed in vitro ratios aligned with these PK data (in contrast to the compendial NGI data) and thus inadvertent selection of "mismatched" biobatches. Two further PK studies were undertaken, supported by the realistic NGI method. With the comparison of test and reference products similarly positioned within their respective product performance distributions, bioequivalence was confirmed in both studies. IVIVCs based on mass fractions as per the realistic NGI method were robust and highly predictive of PK outcomes. Conclusions: The test tiotropium DPI and Spiriva HandiHaler were bioequivalent when equitable biobatch comparisons, based on realistic NGI testing, were performed. The observations from this program support the utility of realistic test methods for inhaled product development.
فهرسة مساهمة: Keywords: anatomical mouth–throat; bioequivalence; breathing profile; in vivo–in vitro correlation; tiotropium
المشرفين على المادة: XX112XZP0J (Tiotropium Bromide)
تواريخ الأحداث: Date Created: 20230626 Date Completed: 20231023 Latest Revision: 20231026
رمز التحديث: 20231215
DOI: 10.1089/jamp.2022.0065
PMID: 37358626
قاعدة البيانات: MEDLINE
الوصف
تدمد:1941-2703
DOI:10.1089/jamp.2022.0065