دورية أكاديمية

Performance of the phonatory deviation diagram in monitoring voice quality before and after voice exercise in individuals with Parkinson's Disease.

التفاصيل البيبلوغرافية
العنوان: Performance of the phonatory deviation diagram in monitoring voice quality before and after voice exercise in individuals with Parkinson's Disease.
عنوان ترانسليتريتد: Desempenho do diagrama de desvio fonatório no monitoramento da qualidade vocal pré e pós exercício vocal em indivíduos com Doença de Parkinson.
المؤلفون: Lima HVSL; Programa de Pós-Graduação em Saúde da Comunicação Humana, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil., Lopes LW; Departamento de Fonoaudiologia, Universidade Federal da Paraíba - UFPB - João Pessoa (PB), Brasil., Silva HJD; Programa de Pós-Graduação em Saúde da Comunicação Humana, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil., Vieira ACC; Departamento de Fonoaudiologia, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil., Cruz TVSD; Departamento de Fonoaudiologia, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil., Gomes AOC; Programa de Pós-Graduação em Saúde da Comunicação Humana, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil., Lira ZS; Programa de Pós-Graduação em Saúde da Comunicação Humana, Centro de Ciências da Saúde, Universidade Federal de Pernambuco - UFPE - Recife (PE), Brasil.
المصدر: CoDAS [Codas] 2023 Jul 17; Vol. 35 (4), pp. e20210224. Date of Electronic Publication: 2023 Jul 17 (Print Publication: 2023).
نوع المنشور: Journal Article
اللغة: Portuguese; English
بيانات الدورية: Publisher: Sociedade Brasileira de Fonoaudiologia Country of Publication: Brazil NLM ID: 101623246 Publication Model: eCollection Cited Medium: Internet ISSN: 2317-1782 (Electronic) Linking ISSN: 23171782 NLM ISO Abbreviation: Codas Subsets: MEDLINE
أسماء مطبوعة: Original Publication: São Paulo : Sociedade Brasileira de Fonoaudiologia
مواضيع طبية MeSH: Parkinson Disease*/complications , Dysphonia*/diagnosis , Dysphonia*/etiology, Humans ; Male ; Middle Aged ; Aged ; Female ; Voice Quality ; Retrospective Studies ; Speech Acoustics ; Phonation
مستخلص: Purpose: To assess the performance of the phonatory deviation diagram and its measurements in monitoring voice quality before and after voice exercise in individuals with Parkinson's Disease.
Methods: Retrospective and documentary study. A sample of 30 subjects was used, 50% male, with a mean age of 62.13 ± 9.05 years. The results of the phonatory deviation diagram were analyzed, in the moments before and after vocal exercise with the pushing technique associated with plosive sounds, considering the area, density, shape and location of the diagram in the quadrants. For comparison purposes, the acoustic parameters of jitter, shimmer, glottal to noise excitation ratio and results of the auditory-perceptual analysis, carried out in previous research, were also considered, in the pre- and post-technical moments.
Results: Despite the fact that there was no difference in the distribution of samples in the diagram, after performing the vocal technique, a change in the displacement of the diagram towards the area of normality was identified in the visual qualitative analysis, and there was an association between the general degree of vocal deviation in the analysis auditory perception and the area of the diagram. There was an improvement in the shimmer values after the vocal technique.
Conclusion: The displacement of the phonatory deviation diagram towards the area of normality corroborated the results in relation to the general degree of dysphonia, evaluated by the auditory-perceptual analysis and the shimmer results, after the vocal technique. Thus, the diagram shows good performance in monitoring voice quality of individuals with Parkinson's.
References: Neurology. 1967 May;17(5):427-42. (PMID: 6067254)
Codas. 2013;25(2):141-8. (PMID: 24408243)
J Acoust Soc Am. 1998 Mar;103(3):1628-39. (PMID: 9514027)
Codas. 2017 Jul 20;29(4):e20160130. (PMID: 28746463)
Rev Neurol. 2020 Jun 1;70(11):393-405. (PMID: 32436206)
Auris Nasus Larynx. 2020 Feb;47(1):7-17. (PMID: 31587820)
Folia Phoniatr Logop. 2011;63(6):305-11. (PMID: 21625144)
Acta Med Port. 2019 Oct 1;32(10):661-670. (PMID: 31625879)
Neurol India. 2018 Mar-Apr;66(Supplement):S26-S35. (PMID: 29503325)
J Voice. 2006 Sep;20(3):380-90. (PMID: 16185841)
J Speech Lang Hear Res. 2000 Jun;43(3):706-20. (PMID: 10877440)
J Voice. 2017 May;31(3):382.e15-382.e26. (PMID: 27742492)
Codas. 2015 May-Jun;27(3):279-84. (PMID: 26222946)
Braz J Otorhinolaryngol. 2018 Jul - Aug;84(4):460-472. (PMID: 28732642)
فهرسة مساهمة: Local Abstract: [Publisher, Portuguese] Verificar o desempenho do diagrama de desvio fonatório e de suas medidas no monitoramento da qualidade da voz, pré e pós exercício vocal, em indivíduos com Doença de Parkinson. [Publisher, Portuguese] Estudo retrospectivo e documental. Utilizou-se uma amostra de 30 sujeitos, sendo 50% do sexo masculino, com média de idade de 62,13 ± 9,05 anos. Foram analisados os resultados do diagrama de desvio fonatório, nos momentos pré e pós exercício vocal com a técnica de empuxo associada aos sons plosivos, considerando-se a área, densidade, forma e localização do diagrama nos quadrantes. Para fins de comparação, os parâmetros acústicos de jitter, shimmer, glottal to noise excitation ratio e resultados da análise perceptivo-auditiva, realizada em pesquisa anterior, também foram considerados, nos momentos pré e pós-técnica. [Publisher, Portuguese] A despeito de não ocorrer diferença na distribuição das amostras no diagrama, após realização da técnica vocal, foi identificada, na análise qualitativa visual, mudança no deslocamento do diagrama em direção à área de normalidade e houve associação entre o grau geral do desvio vocal da análise perceptivoauditiva e a área do diagrama. Houve melhora nos valores de shimmer, após a técnica vocal. [Publisher, Portuguese] O deslocamento do diagrama de desvio fonatório em direção à área de normalidade corroborou os resultados em relação ao grau geral de disfonia avaliado pela análise perceptivoauditiva e os resultados de shimmer, após a técnica vocal empregada. Desse modo, o diagrama de desvio fonatório apresentou bom desempenho no monitoramento da qualidade vocal de indivíduos com Parkinson.
تواريخ الأحداث: Date Created: 20230719 Date Completed: 20230721 Latest Revision: 20230826
رمز التحديث: 20240628
مُعرف محوري في PubMed: PMC10446749
DOI: 10.1590/2317-1782/20232021224pt
PMID: 37466502
قاعدة البيانات: MEDLINE
الوصف
تدمد:2317-1782
DOI:10.1590/2317-1782/20232021224pt